Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) atlas for ultrasound (US) qualitatively describes the echogenicity and attenuation of a mass, where fat lobules serve as a standard for comparison. This study aimed to estimate acoustic properties of breast fat under clinical imaging conditions to determine the degree to which properties vary among patients.
Methods: Twenty-four women with solid breast masses scheduled for biopsy were scanned with a Siemens S2000 scanner and 18L6 linear array transducer (Siemens Medical Solutions, Malvern, PA). Offline analysis estimated the attenuation coefficient and backscatter coefficients (BSCs) from breast fat using the reference phantom method. The average BSC was calculated over 6 to 12 MHz to objectively quantify the BI-RADS US echo pattern descriptor, and effective scatterer diameters were also estimated.
Results: A power law fit to the attenuation coefficient versus frequency yielded an attenuation coefficient of 1.28 dB·cm(-1) MHz(-0.73). The mean attenuation coefficient versus frequency slope ± SD at 7 MHz was 0.73 ± 0.23 dB·cm(-1) MHz(-1), in agreement with previously reported values. The BSC versus frequency showed close agreement among all patients, both in magnitude and frequency dependence, with a power law fit of (0.6 ± 0.25) ×10(-4) sr(-1) cm(-1) MHz(-2.49). The average backscatter in the 6-12-MHz range was 0.004 ± 0.002 sr(-1) cm(-1). The mean effective scatterer diameter for fat was 60.2 ± 9.5 μm.
Conclusions: The agreement in parameter estimates for breast fat among these patients supports the use of fat as a standard for comparison with tumors. Results also suggest that objective quantification of these BI-RADS US descriptors may reduce subjectivity when interpreting B-mode image data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4618705 | PMC |
http://dx.doi.org/10.7863/ultra.14.07039 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!