Appropriate reference values of hair trace element content are required for correct interpretation of biomonitoring data. The primary objective of the current study was to estimate the reference values of selected essential trace elements in hair of adult Russian population. Involved in current investigation were 7256 occupationally non-exposed adults aged from 20 to 60 years and living in the European part of Russia. Occipital hair essential metal and metalloid (Co, Cr, Cu, Fe, Mn, Se, V, Zn) content was estimated using inductively coupled plasma mass spectrometry. The reference ranges were calculated in accordance with the International Union of Pure and Applied Chemistry (IUPAC) recommendations. Women were characterized by 55, 18, 58, and 7% higher values of hair Co, Cu, Mn, and Zn content as compared to the values observed in men. At the same time, hair Cr, Fe, Se, and V concentration in men significantly exceeded the respective female values by 65, 13, 20, and 56%. Consequently, the reference ranges of essential hair trace elements content should be separately calculated for both men and women. The obtained reference ranges for hair Co, Cr, Cu, Fe, Mn, Se, V, and Zn in men were 0.11-0.67, 0.007-0.045, 10.4-22.6, 11.1-40.5, 0.24-1.05, 0.089-0.480, 0.014-0.083, and 125.7-262.8 μg/g, respectively. The respective values estimated for women were 0.06-0.40, 0.011-0.085, 12.1-44.5, 8.9-25.6, 0.32-2.05, 0.094-0.504, 0.010-0.056, and 140.0-315.1 μg/g. The reference ranges for hair Co (0.07-0.50), Cr (0.009-0.073), Cu (11.8-29.2), Fe (9.6-31.5), Mn (0.29-1.76), Se (0.093-0.482), V (0.011-0.069), and Zn (134.7-301.9) content (μg/g) in the general cohort were also calculated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10661-015-4903-x | DOI Listing |
Int J Syst Evol Microbiol
January 2025
China General Microbiological Culture Collection Center (CGMCC), Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, PR China.
Five aerobic, Gram-stain-negative bacterial strains, designated as C3-2-a3, B3-2-R+30, C3-2-a4, C3-2-M3 and C3-2-M8, were isolated from the coastal soil of LungmuCo Lake in the Tibet Autonomous Region, PR China. Phylogenetic analyses based on 16S rRNA genes and genomes indicated that these isolates belonged to the genus and showed a high similarity to LNNU 24178 (99.01%), RD2P54 (98.
View Article and Find Full Text PDFIntroduction And Objectives: The fractional exhaled fraction of nitric oxide (FeNO) is used in clinical practice for asthma diagnosis, phenotyping, and therapeutic management. Therefore, accurate thresholds are crucial. The normal FeNO values over lifespan in a respiratory healthy population and the factors related to them remain unclear.
View Article and Find Full Text PDFPediatr Pulmonol
January 2025
Pulmonary and Sleep Medicine, DeVos Children's Hospital, Grand Rapids, Michigan, USA.
Objective: We prospectively monitored rates of change for growth, body mass and composition, muscle strength, and FEV1 in 6-11-year-olds initiating ETI therapy, comparing them to those of US reference children. We assessed factors potentially contributing to rate of change and report ranges of individual variation.
Methods: Body composition was assessed using bioelectrical impedance analysis (BIA), and rates of change were analyzed using linear mixed effects regression models.
Clin Chem Lab Med
January 2025
Coordinator of the Italian Study Group of Cardiac Biomarkers, Scuola Superiore Sant'Anna and Fondazione CNR - Regione Toscana G. Monasterio, Pisa, Italy.
Objectives: The present multicenter study was designed to evaluate the analytical performance and the 99th percentile value of the reference healthy population i.e., 99th percentile upper reference limit of the MAGLUMI CLIA high-sensitivity cardiac troponin I (hs-cTnI) method.
View Article and Find Full Text PDFMuscle Nerve
January 2025
Department of Neurology, Teikyo University School of Medicine, Tokyo, Japan.
Introduction: Extrapolated reference values (E-Ref) procedure is a new method for determining the cutoff value without collecting the control data. We tried to apply this method to determine the cutoff value for the distal motor latency of the median nerve (median DML). During this process, we found two pitfalls of the E-Ref method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!