According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4617115 | PMC |
http://dx.doi.org/10.1590/1414-431X20144337 | DOI Listing |
BMC Cardiovasc Disord
January 2025
Department of Computed Tomography and Magnetic Resonance, Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
Objectives: This study aimed to evaluate the feasibility and accuracy of non-electrocardiogram (ECG)-triggered chest low-dose computed tomography (LDCT) with a kV-independent reconstruction algorithm in assessing coronary artery calcification (CAC) degree and cardiovascular disease risk in patients receiving maintenance hemodialysis (MHD).
Methods: In total, 181 patients receiving MHD who needed chest CT and coronary artery calcium score (CACS) scannings sequentially underwent non-ECG-triggered, automated tube voltage selection, high-pitch chest LDCT with a kV-independent reconstruction algorithm and ECG-triggered standard CACS scannings. Then, the image quality, radiation doses, Agatston scores (ASs), and cardiac risk classifications of the two scans were compared.
Photochem Photobiol
January 2025
Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Photodynamic therapy (PDT) has shown promise as an adjuvant treatment for malignant pleural mesothelioma when combined with surgical resection. Accurate light dosimetry is critical for treatment efficacy. This study presents an improved method for analyzing light fluence distribution in pleural PDT using a standardized anatomical coordinate system and advanced computational modeling.
View Article and Find Full Text PDFNan Fang Yi Ke Da Xue Xue Bao
January 2025
School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China.
Objectives: We present a new low-dose CT reconstruction method using sub-pixel and anisotropic diffusion.
Methods: The sub-pixel intensity values and their second-order differences were obtained using linear interpolation techniques, and the new gradient information was then embedded into an anisotropic diffusion process, which was introduced into a penalty-weighted least squares model to reduce the noise in low-dose CT projection data. The high-quality CT image was finally reconstructed using the classical filtered back-projection (FBP) algorithm from the estimated data.
Appl Radiat Isot
March 2025
Instituto de Física Corpuscular (CSIC-Universidad de Valencia), Valencia, Spain.
This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in nuclear astrophysics experiments at CERN, is being optimized for detecting and imaging 478 keV gamma-rays, critical for accurate BNCT dosimetry. Detailed Monte Carlo simulations were used to optimize the i-TED detector configuration and enhance its performance in the challenging radiation environment typical of BNCT.
View Article and Find Full Text PDFAnn Surg Oncol
January 2025
Section of Plastic and Reconstructive Surgery, Department of Surgery, University of Michigan Health Systems, Ann Arbor, MI, USA.
Background: The placement of breast implants in a prepectoral plane has become increasingly popular in breast reconstruction, although data on how this affects radiation delivery in women with breast cancer are limited. This study aimed to assess the dosimetric differences in radiation plans for immediate breast reconstruction between prepectoral and subpectoral implants.
Methods: In this study, a retrospective review and dosimetric analysis of patients with breast cancer who underwent immediate implant-based reconstruction and postmastectomy radiation therapy (PMRT) were performed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!