Objective: The purpose of this case study was to demonstrate hearing preservation of a subject who was implanted with a 10-mm short electrode cochlear implant that was determined to be malfunctioning at 6 months postimplantation and was explanted and reimplanted with a 16-mm short electrode device.Study Design: Single-subject case study.Setting: Research hospital.Patient: A 60-year old female with a history of gradual progressive bilateral steeply sloping sensorineural hearing loss.Intervention: Rehabilitative.Main Outcome Measure(s): Audiometric data and speech perception in quiet and in noise were collected pre- and postoperatively at 3 and 6 months with the 10-mm short electrode device and pre-explantation and postoperatively at 3, 6, and 12 months with the 16-mm short electrode device.Results: Functional hearing preservation was accomplished following surgical implantation of both short electrode devices. Overall, the subject had a 22 dB HL total shift in pure-tone-average (0.125–1 kHz) after two cochlear implant surgeries. Speech perception growth was limited over the 6 months the subject was implanted with the 10-mm short electrode device. After 3 months of experience with the 16-mm short electrode device, the subject experienced significant improvements in both speech perception in quiet and in noise.Conclusions: The inner ear might be more robust than once thought, as was determined through preservation of residual hearing after implantation of two hearing preservation cochlear implants and one device explantation. Furthermore, it is important that hearing professionals remain cognizant of unusual speech perception patterns associated with the cochlear implant. Key Words: Hearing preservation—Residual hearing—Short electode. [Corrected]
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4659721 | PMC |
http://dx.doi.org/10.1097/MAO.0000000000000867 | DOI Listing |
Chem Sci
December 2024
School of Chemistry and Chemical Engineering, Shandong University Jinan 250100 China
The development of universal electrochemical sensing platforms with high sensitivity and specificity is of great significance for advancing practical disease diagnostic methods and devices. Exploring the structural properties of electrode materials and their interaction with biomolecules is essential to developing novel and distinctive analytical approaches. Here, we innovatively investigated the effect of DNA length and configuration on DNA molecule transfer into the nanostructure of a nanoporous gold (NPG) electrode.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
State Key Laboratory of Electroanalytical Chemistry, Jilin Province Key Laboratory of Low Carbon Chemical Power, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, Jilin, China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, Anhui, China. Electronic address:
Background: Scanning electrochemical microscopy (SECM) is a kind of scanning probe technology that enables the obtainment of surface morphology and electrochemical information by recording changes in Faraday current triggered by the movement of probe.
Results: In this work, flexible disk ultramicroelectrode (UME) with highly repeatable geometry are fabricated through a simple and universal strategy that involves vacuum pulling the glass capillaries inserted with platinum wire (gold wire, carbon fiber, etc.), followed by a rapidly heated sealing and polishing process.
Neurosci Res
January 2025
Center for Brain Behavior and Metabolism, University of Lübeck, Germany. Electronic address:
Pronouns create cohesive links in discourse by referring to previously mentioned elements. Here, we focus on pronominalization during speech production in three experiments employing ERP and fMRI methodologies. Participants were asked to produce two short sentences describing a man or woman using an object.
View Article and Find Full Text PDFInt J Med Sci
January 2025
Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, MALAYSIA.
The finger photoplethysmography fitness index (PPGF), a marker of peripheral vascular function, has been linked to heart rate (HR) variability. However, the influence of acute HR changes on resting PPGF, a purported indicator of local blood flow, remains unclear. This study aimed to determine the influence of acute HR changes on resting PPGF.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China.
Vertical organic electrochemical transistors (vOECTs) have received widespread attention in bioelectronics, wearable, and neuromorphic electronics due to their high transconductance (), low driving voltage, and biocompatibility. As key parameters of vOECTs, and switching speed (or transient time, τ) are vital for achieving satisfying performance in various practical applications. Here we employ vOECTs with varying top electrode widths for effective and switching speed modulation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!