No previous reports have observed inside the root canal using both optical coherence tomography (OCT) and x-ray microcomputed tomography (μCT) for the same sample. The purpose of this study was to clarify both OCT and μCT image properties from observations of the same root canal after resin core build-up treatment. As OCT allows real-time observation of samples, gap formation may be able to be shown in real time. A dual-cure, one-step, self-etch adhesive system bonding agent, and dual-cure resin composite core material were used in root canals in accordance with instructions from the manufacturer. The resulting OCT images were superior for identifying gap formation at the interface, while μCT images were better to grasp the tooth form. Continuous tomographic images from real-time OCT observation allowed successful construction of a video of the resin core build-up procedure. After 10 to 12 s of light curing, a gap with a clear new signal occurred at the root-core material interface, proceeding from the coronal side (6 mm from the cemento-enamel junction) to the apical side of the root.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1117/1.JBO.20.10.107001 | DOI Listing |
Phys Rev Lett
December 2024
National University of Singapore, Department of Physics, Singapore 117551.
We uncover emergent universality arising in the equilibration dynamics of multimode continuous-variable systems. Specifically, we study the ensemble of pure states supported on a small subsystem of a few modes, generated by Gaussian measurements on the remaining modes of a globally pure bosonic Gaussian state. We find that beginning from highly entangled, complex global states, such as random Gaussian states and product squeezed states coupled via a deep array of linear optical elements, the induced ensemble attains a universal form, independent of the choice of measurement basis: it is composed of unsqueezed coherent states whose displacements are distributed normally and isotropically, with variance depending on only the particle-number density of the system.
View Article and Find Full Text PDFGraefes Arch Clin Exp Ophthalmol
January 2025
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, 618# Fengqi East Road, Hangzhou, 310000, Zhejiang, China.
Purpose: To calculate the crystalline lens power and astigmatism, as well as their changes following cycloplegia, in individuals with myopia using swept-source optical coherence tomography (SS-OCT).
Methods: Participants were divided into two groups according to axial length (AL). Crystalline lens parameters, including power, lens thickness (LT), anterior chamber depth (ACD), and astigmatism, were measured with SS-OCT and analysed before and after cycloplegia.
Transl Vis Sci Technol
January 2025
STZ eyetrial at the Centre for Ophthalmology, Tuebingen, Germany.
Purpose: Reports of gene therapy-associated retinal atrophies and inflammation have highlighted the importance of preclinical safety assessments of adeno-associated virus (AAV) vector systems. We evaluated in nonhuman primates (NHPs) the ocular safety and toxicology of a novel AAV gene therapy targeting retinitis pigmentosa caused by mutations in PDE6A, which has since been used in a phase I/II clinical trial (NCT04611503).
Methods: A total of 34 healthy cynomolgus animals (Macaca fascicularis) were treated with subretinal injections of rAAV.
J Glaucoma
January 2025
Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI.
Precis: Current optical coherence tomography normative sample data may not represent diverse human optic nerve anatomy to accurately classify all individuals with true glaucomatous optic neuropathy.
Purpose: To compare optic nerve head (ONH) measurements between published values from an optical coherence tomography (OCT) normative database and a more diverse cohort of healthy individuals.
Patients And Methods: ONH parameters from healthy participants of the Michigan Screening and Intervention for Glaucoma and Eye Health through Telemedicine (MI-SIGHT) program and the Topcon Maestro-1 normative cohort were compared.
Catheter Cardiovasc Interv
January 2025
State Key Laboratory of Frigid Zone Cardiovascular Diseases, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Background: Biodegradable polymer stents may reduce the risk of neoatherosclerosis and stent thrombosis. Limited data is available for biodegradable polymer sirolimus-eluting stent (BP-SES) and durable polymer drug-eluting stents (DP-EES) in chronic total occlusions (CTO).
Aim: This study was to evaluate healing patterns of BP-SES versus DP-EES in CTO at 3 and 13 months based on optical coherence tomography (OCT).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!