A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid chiral separation of racemic cetirizine in human plasma using subcritical fluid chromatography-tandem mass spectrometry. | LitMetric

Rapid chiral separation of racemic cetirizine in human plasma using subcritical fluid chromatography-tandem mass spectrometry.

J Pharm Biomed Anal

Department of Pharmaceutical Analysis, College of Pharmacy, Chung-Ang University, 221 Heukseok-Dong, Dongjak-Gu, Seoul 156-756, Republic of Korea. Electronic address:

Published: January 2016

A method for fast chiral separation of cetirizine and quantitation of levocetirizine in human plasma using subcritical fluid chromatography with tandem mass spectrometry was developed and validated. The chromatographic separation was performed using a Chiralpak IE column (2.1 mm×150 mm, 5 μm) with an isocratic elution of CO2/organic modifier (55/45, v/v) at a flow rate of 0.85 mL/min. The organic modifier was composed of water/methanol (5/95, v/v). The makeup flow was optimized at water/methanol (10/90, v/v) and 0.2 mL/min. The most influential parameters on the separation of cetirizine affecting resolution, retention time and sensitivity were selected by fractional factorial design. The 3 selected factors were optimized by response surface methodology. Tandem mass spectrometry was used at electrospray ionization, positive ion mode, and multiple-reaction monitoring mode. Isotope-labeled cetirizine-d4 was used as the internal standard. The sample preparation of human plasma was conducted by solid phase extraction of hydrophilic-lipophilic balance (HLB) type. The developed method was validated for selectivity, linearity, precision, accuracy, recovery, limit of quantitation (LOQ), and limit of detection (LOD). The real human plasma samples were analyzed and the pharmacokinetic results were compared with results of previous research. The developed method was found to be reliable based on the similarity between the results of the current and previous methods. The chiral separation for cetirizine and economic feasibility were compared with those of previous studies using normal phase-HPLC or reversed phase-HPLC. The established analytical method could be successfully applied to pharmacokinetic study with reduction in the analysis time and costs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2015.09.012DOI Listing

Publication Analysis

Top Keywords

human plasma
16
chiral separation
12
mass spectrometry
12
separation cetirizine
12
plasma subcritical
8
subcritical fluid
8
tandem mass
8
developed method
8
compared previous
8
separation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!