A Culture-Behavior-Brain Loop Model of Human Development.

Trends Cogn Sci

State Key Laboratory of Cognitive Neuroscience and Learning, IDG/McGovern Institute for Brain Research, Beijing Normal University, Beijing, 100875, China. Electronic address:

Published: November 2015

Increasing evidence suggests that cultural influences on brain activity are associated with multiple cognitive and affective processes. These findings prompt an integrative framework to account for dynamic interactions between culture, behavior, and the brain. We put forward a culture-behavior-brain (CBB) loop model of human development that proposes that culture shapes the brain by contextualizing behavior, and the brain fits and modifies culture via behavioral influences. Genes provide a fundamental basis for, and interact with, the CBB loop at both individual and population levels. The CBB loop model advances our understanding of the dynamic relationships between culture, behavior, and the brain, which are crucial for human phylogeny and ontogeny. Future brain changes due to cultural influences are discussed based on the CBB loop model.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.tics.2015.08.010DOI Listing

Publication Analysis

Top Keywords

loop model
16
cbb loop
16
behavior brain
12
model human
8
human development
8
cultural influences
8
culture behavior
8
brain
6
culture-behavior-brain loop
4
model
4

Similar Publications

Purpose: This brief report aims to summarize and discuss the methodologies of eXplainable Artificial Intelligence (XAI) and their potential applications in surgery.

Methods: We briefly introduce explainability methods, including global and individual explanatory features, methods for imaging data and time series, as well as similarity classification, and unraveled rules and laws.

Results: Given the increasing interest in artificial intelligence within the surgical field, we emphasize the critical importance of transparency and interpretability in the outputs of applied models.

View Article and Find Full Text PDF

We have recently demonstrated a novel anaerobic NADH-dependent haem breakdown reaction, which is carried out by a range of haemoproteins. The Yersinia enterocolitica protein, HemS, is the focus of further research presented in the current paper. Using conventional experimental methods, bioinformatics, and energy landscape theory (ELT), we provide new insight into the mechanism of the novel breakdown process.

View Article and Find Full Text PDF

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Ultraprecision multi-axis CARIC control strategy with application to a nano-accuracy air-bearing motion stage.

ISA Trans

January 2025

State Key Laboratory of Tribology in Advanced Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China; Beijing Key Laboratory of Transformative High-end Manufacturing Equipment and Technology, Tsinghua University, Beijing, 100084, China. Electronic address:

Multi-axis contouring control is crucial for ultraprecision manufacturing industries, contributing to meeting the ever-increasingly stringent performance requirements. In this article, a novel contouring adaptive real-time iterative compensation (CARIC) method is proposed to achieve extreme multi-axis contouring accuracy, remarkable trajectory generalization, disturbance rejection, and parametric adaptation simultaneously. Specifically, control actions generated by CARIC consist of robust feedback, adaptive feedforward, and online trajectory compensation components.

View Article and Find Full Text PDF

Osseointegration for transfemoral amputees: Influence of femur length and implant sizing on bone-implant contact and alignment.

Injury

January 2025

Department of Orthopedic Surgery, McGovern Medical School, UTHealth Science Center at Houston, 5420 West Loop S. Suite 1300, Bellaire, TX, 77401, USA. Electronic address:

Introduction: Clinical data on osseointegration (OI) for limb replacement indicates a concerning increase in mechanical complications after five years post-implantation. Since adequate bone-implant contact and proper implant alignment are critical factors for successful osseointegration, it is essential to identify the factors influencing these outcomes. This study aimed to assess the effects of residual femur length and implant sizing on bone-implant contact and implant alignment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?