Manual palpation is a common and very informative diagnostic tool based on estimation of changes in the stiffness of tissues that result from pathology. In the case of a small lesion or a lesion that is located deep within the body, it is difficult for changes in mechanical properties of tissue to be detected or evaluated via palpation. Furthermore, palpation is non-quantitative and cannot be used to localize the lesion. Magnetic Resonance-guided Focused Ultrasound (MRgFUS) can also be used to evaluate the properties of biological tissues non-invasively. In this study, an MRgFUS system combines high field (7T) MR and 3 MHz focused ultrasound to provide high resolution MR imaging and a small ultrasonic interrogation region (~0.5 x 0.5 x 2 mm), as compared with current clinical systems. MR-Acoustic Radiation Force Imaging (MR-ARFI) provides a reliable and efficient method for beam localization by detecting micron-scale displacements induced by ultrasound mechanical forces. The first aim of this study is to develop a sequence that can concurrently quantify acoustic radiation force displacements and image the resulting transient shear wave. Our motivation in combining these two measurements is to develop a technique that can rapidly provide both ARFI and shear wave velocity estimation data, making it suitable for use in interventional radiology. Secondly, we validate this sequence in vivo by estimating the displacement before and after high intensity focused ultrasound (HIFU) ablation, and we validate the shear wave velocity in vitro using tissue-mimicking gelatin and tofu phantoms. Such rapid acquisitions are especially useful in interventional radiology applications where minimizing scan time is highly desirable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4594908PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0139667PLOS

Publication Analysis

Top Keywords

shear wave
16
radiation force
12
focused ultrasound
12
acoustic radiation
8
wave velocity
8
interventional radiology
8
concurrent visualization
4
visualization acoustic
4
force displacement
4
shear
4

Similar Publications

High-Performance Shear Mode Ultrasonic Transducer Operating at Ultrahigh Temperature Fabricated with BiSiO Piezoelectric Crystal.

ACS Appl Mater Interfaces

December 2024

Center for Optics Research and Engineering, State Key Laboratory of Crystal Materials, Shandong University, Qingdao 266237, China.

Shear mode ultrasonic waves are in high demand for structural health monitoring (SHM) applications owing to their nondispersive characteristics, singular mode, and minimal energy loss, especially in harsh environments. However, the generation and detection of a pure shear wave using conventional piezoelectric materials present substantial challenges because of their complex piezoelectric response, involving multiple modes. Herein, we introduce a high-quality piezoelectric crystal BiSiO (BSO), exhibiting a robust piezoelectric response ( = 45.

View Article and Find Full Text PDF

Correlation between ultrasonography and elastography parameters and molecular subtypes of breast cancer in young women.

Ann Med

December 2025

Department of Ultrasonographl, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, Shanxi Province, China.

Objective: To explore the differences of conventional ultrasound characteristics, elastic imaging parameters and clinicopathological characteristics of distinct molecular subtypes of breast cancer in young women, and to identify imaging parameters that exhibited significant associations with each molecular subtype.

Methods: We performed a retrospective analysis encompassing 310 young women with breast cancer. Observations were made regarding the ultrasonography and elastography characteristics of the identified breast lesions.

View Article and Find Full Text PDF

Objective: This study explored the value of stomach ultrasound reporting and data system (Su-RADS) and two-dimensional shear wave elastography (2D-SWE) in the diagnosis of benign and malignant lesions of the gastric wall, evaluating the feasibility of combining the two methods for the diagnosis of gastric wall lesions.

Methods: 113 patients with gastric wall lesions were examined after oral gastric ultrasound contrast agent, and the grades of the gastric wall lesions were classified according to Su-RADS. Moreover, 2D-SWE was performed to measure the E value of the lesions.

View Article and Find Full Text PDF

Wave ripples can provide valuable information on their formative hydrodynamic conditions in past subaqueous environments by inverting dimension predictors. However, these inversions do not usually take the mixed non-cohesive/cohesive nature of sediment beds into account. Recent experiments involving sand-kaolinite mixtures have demonstrated that wave-ripple dimensions and the threshold of motion are affected by bed clay content.

View Article and Find Full Text PDF