Experimental and numerical characterization of the water flow in spacer-filled channels of spiral-wound membranes.

Water Res

Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Julianalaan 67, 2628, BC Delft, The Netherlands. Electronic address:

Published: December 2015

Micro-scale flow distribution in spacer-filled flow channels of spiral-wound membrane modules was determined with a particle image velocimetry system (PIV), aiming to elucidate the flow behaviour in spacer-filled flow channels. Two-dimensional water velocity fields were measured in a flow cell (representing the feed spacer-filled flow channel of a spiral wound reverse osmosis membrane module without permeate production) at several planes throughout the channel height. At linear flow velocities (volumetric flow rate per cross-section of the flow channel considering the channel porosity, also described as crossflow velocities) used in practice (0.074 and 0.163 m·s(-1)) the recorded flow was laminar with only slight unsteadiness in the upper velocity limit. At higher linear flow velocity (0.3 m·s(-1)) the flow was observed to be unsteady and with recirculation zones. Measurements made at different locations in the flow cell exhibited very similar flow patterns within all feed spacer mesh elements, thus revealing the same hydrodynamic conditions along the length of the flow channel. Three-dimensional (3-D) computational fluid dynamics simulations were performed using the same geometries and flow parameters as the experiments, based on steady laminar flow assumption. The numerical results were in good agreement (0.85-0.95 Bray-Curtis similarity) with the measured flow fields at linear velocities of 0.074 and 0.163 m·s(-1), thus supporting the use of model-based studies in the optimization of feed spacer geometries and operational conditions of spiral wound membrane systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2015.09.036DOI Listing

Publication Analysis

Top Keywords

flow
19
spacer-filled flow
12
flow channel
12
channels spiral-wound
8
flow channels
8
measured flow
8
flow cell
8
spiral wound
8
linear flow
8
0074 0163
8

Similar Publications

Reply Letter to "Pulsatile Flow During Venoarterial-Extracorporeal Membrane Oxygenation: A Topic in Need of Attention".

ASAIO J

October 2024

Division of Cardiac Surgery Department of Surgery Johns Hopkins Hospital, Baltimore, Maryland Division of Neurosciences Critical Care Department of Neurology, Neurosurgery, Anesthesiology and Critical Care Medicine Johns Hopkins Hospital, Baltimore, Maryland.

View Article and Find Full Text PDF

Background: Complex lower extremity defects are difficult to cover and often require multiple free tissue transfers. Chimeric anterolateral thigh free flaps (ALTF) and peroneal artery perforator free flaps (PAPF) have been designed specifically as an alternative for reconstruction with arterial end-to-side (ETS) anastomosis. We aimed to assess our institutional experience with this technique and to define its role in complex lower extremity reconstruction.

View Article and Find Full Text PDF

Introduction: During hemodialysis (HD), the presence of clots in the dialyzer can diminish the effective surface area of the device. In severe cases, clot formation in the circuit can halt treatment and lead to blood loss in the system. Thus, ensuring proper anticoagulation during HD is crucial to prevent clotting in the circuit while safeguarding the patient from bleeding risks.

View Article and Find Full Text PDF

Self-propelled micro/nanomotors (MNMs) represent a groundbreaking advancement in precision drug delivery, offering potential solutions to persistent challenges such as systemic toxicity, limited bioavailability, and nonspecific distribution. By transforming various energy sources into mechanical motion, MNMs are able to autonomously navigate through complex physiological environments, facilitating targeted delivery of therapeutic agents to previously inaccessible regions. However, to achieve efficient in vivo drug delivery, biomedical MNMs must demonstrate their ability to overcome crucial physiological barriers encompassing mucosal surfaces, blood flow dynamics, vascular endothelium, and cellular membrane.

View Article and Find Full Text PDF

Spatial stable isotope tracing metabolic imaging is a cutting-edge technique designed to investigate tissue-specific metabolic functions and heterogeneity. Traditional matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) techniques often struggle with low coverage of low-molecular-weight (LMW) metabolites, which are often crucial for spatial metabolic studies. To address this, we developed a high-coverage spatial isotope tracing metabolic method that incorporates optimized matrix selection, sample preparation protocols, and enhanced post-ionization (MALDI2) techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!