Test-Retest Reliability and Minimal Detectable Change for the 10-Meter Walk Test in Older Adults With Parkinson's disease.

J Geriatr Phys Ther

Doctor of Physical Therapy Program, Department of Kinesiology, College of Agriculture, Health and Natural Resources, University of Connecticut, Storrs.

Published: February 2018

Background And Purpose: Measurement of gait performance in individuals with Parkinson's disease (PD) can be challenging because of the daily fluctuations in performance and the progressive nature of the condition. The 10-Meter Walk Test (10MWT) is commonly used to measure gait speed of individuals with gait limitations. Existing research on the 10MWT in individuals with PD controls for many variables inherent to this condition, rendering the results of this test in settings where these variables are not controlled questionable. The purpose of this study was to estimate under commonly encountered clinical conditions the test-retest reliability and the minimal detectable change (MDC) of gait speed and step frequency determined during the 10MWT in individuals with PD.

Methods: The 10MWT was administered by 2 testers, on 35 participants, across 2 sessions, separated by 5 to 14 days. Gait speed was measured using a hand-held stopwatch, and step frequency was assessed through visual observation. Test-retest reliability was calculated using the intraclass correlation coefficient (ICC) and the MDC was calculated using the standard error of measurement (SEM).

Results And Discussion: Comfortable and fast gait speeds demonstrated excellent reliability between sessions (ICC = 0.92 and 0.96, respectively). The corresponding MDCs were 0.22 and 0.23 m/s, respectively. The test-retest reliability for step frequency was moderate for comfortable gait speed and good for fast gait speeds (ICC = 0.73 and 0.82, respectively). The corresponding MDCs were 15.1 and 17.4 steps per minute for comfortable and fast step frequency, respectively.

Conclusions: Under both comfortable and fast conditions, measurements of gait speed and step frequency during the 10MWT are reliable between sessions in individuals with PD.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JPT.0000000000000068DOI Listing

Publication Analysis

Top Keywords

gait speed
20
step frequency
20
test-retest reliability
16
comfortable fast
12
gait
9
reliability minimal
8
minimal detectable
8
detectable change
8
10-meter walk
8
walk test
8

Similar Publications

Background: In osteoarthritis quadriceps strength is an important outcome to assess exercise capacity and recovery after arthroplasty. However, its measurement is limited due to lack of time and the need for trained personnel and equipment whose accuracy is verified.

Objectives: To find out the determinants of a reduced quadriceps strength and to establish a score to screen for it.

View Article and Find Full Text PDF

Unlabelled: This study examines how power training affects estimated bone strength, revealing that females benefit more than males, especially in the upper limbs (radius). These findings highlight the importance of designing sex-specific exercise programs to enhance bone health. Further research is needed to optimize training duration and address site-specific differences.

View Article and Find Full Text PDF

Utilizing Rhythmic Haptic Cueing in Arm Swing Training to Improve Gait Speed Among Older Adults.

Ann Biomed Eng

December 2024

Department of Mechanical Engineering, The Biorobotics and Biomechanics Lab, University of Maine, 168 College Ave, Orono, ME, 04469, USA.

Purpose: Current gait rehabilitation protocols for older adults typically attempt to effect changes in leg movements, while the role of arm movements is often ignored despite evidence of the neurological coupling of the upper and lower extremities. In the present work, we examine the effectiveness of a novel wearable haptic cueing system that targets arm swing to improve various gait parameters in older adults.

Methods: Twenty participants (  years) were recruited to analyze their gait during normal and fast walking without haptic cueing.

View Article and Find Full Text PDF

This study examined the activity profile of elite hurling referees during games in the National Hurling League (NHL) and All-Ireland Championship (AIC) and across all divisions of the NHL and phases of the AIC. Temporal changes between the first and second half and across the four quarters were also examined. Data were collected from 36 referees using 10-Hz global positioning system technology during 106 NHL and 85 AIC games and analyzed for duration, total distance, very low-speed movement (<0.

View Article and Find Full Text PDF

Objectives: To compare the effects of explosive and strength resistance training on neuromuscular and functional parameters in older adults and to analyze the relationship between changes in walking speed and improvements in plantar flexor (PF) neuromuscular parameters following interventions.

Methods: In total, 40 participants were randomly assigned to either an explosive resistance training group (EXG, n = 18; age = 80.41 ± 10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!