Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Intercostal artery blood flow supplies the external and internal intercostal muscles, which are inspiratory and expiratory muscles. Intercostal blood flow measured by the echo-Doppler (ED) technique has not previously been reported in humans. This study describes the feasibility of this measurement during free and loaded breathing in healthy subjects. Systolic, diastolic and mean blood flows were measured in the eighth dorsal intercostal space during free and loaded breathing using the ED technique. Flows were calculated as the product of the artery intraluminal surface and blood velocity. Ten healthy subjects (42 ± 13·6 years) were included. Integrated electromyogram (iEMG), arterial pressure, cardiac frequency and breathing pattern were also recorded. Mean blood flows were 3·5 ± 1·2 ml min at rest, 6 ± 2·6 ml min while breathing through a combined inspiratory and expiratory resistance and 4·0 ± 1·3 ml min 1 min after unloading. Diastolic blood flow was about one-third the systolic blood flow. The changes in blood flows were consistent with those in iEMG. No change in mean blood flow was observed between inspiration and expiration, suggesting a balance in the perfusion of external and internal muscles during breathing. In conclusion, ED is a feasible technique for non-invasive, real-time measurement of intercostal blood flow in humans. In healthy subjects, mean blood flow appeared tightly matched to iEMG activity. This technique may provide a way to assess the vascular adaptations induced by diseases in which respiratory work is increased or cardiac blood flow altered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cpf.12298 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!