Background: Obstructive sleep apnea syndrome is a major public health problem. The morphometric model and the Sleep Apnea Clinical Score are widely used to evaluate adults; however, neither of these tools has been validated in a Mexican population.

Objective: To determine the diagnostic value of the morphometric model and the Sleep Apnea Clinical Score and compare them with conventional clinical instruments.

Methods: A total of 97 individuals were recruited prospectively. Initial screening excluded 36, of whom nine were subjects without apnea; the remaining 52 were consecutive patients with obstructive sleep apnea syndrome diagnosed by nocturnal polysomnography. Diagnostic values of each test were calculated.

Results: Obstructive sleep apnea syndrome patients had significantly higher scores with both instruments than controls: morphometric model: 61.3 (95% CI: 45.5-75.3) vs. 41.0 (95% CI: 35.6-45.6); Sleep Apnea Clinical Score: 45.3 (95% CI: 39.5-40.3) vs. 36 (95% CI: 34.0-36.5), respectively. For severe cases, the best cutoff point for morphometric model was 46, with a sensitivity of 81% (95% CI: 62.5-92.6) and specificity of 46.7% (95% CI: 66.4-100), while for Sleep Apnea Clinical Score it was > 48, with a sensitivity of 61% (95% CI: 46.1-74.2) and specificity of 80.4% (95% CI: 66-90.6).

Conclusions: A morphometric model value of ≥ 46 or an adjusted neck circumference (Sleep Apnea Clinical Score) > 48 were adequate for diagnosing obstructive sleep apnea syndrome.

Download full-text PDF

Source

Publication Analysis

Top Keywords

sleep apnea
40
morphometric model
24
obstructive sleep
20
apnea syndrome
20
apnea clinical
20
clinical score
20
apnea
11
sleep
10
diagnostic morphometric
8
adjusted neck
8

Similar Publications

Introduction: Moderate-to-severe obstructive sleep apnea (OSA) affects a large segment of the US population and is characterized by repetitive and reversible obstruction of the upper airway during sleep. Untreated OSA is associated with increased incidence of heart attack, stroke, and motor vehicle accidents due to sleepiness. Continuous positive airway pressure is often prescribed, but most patients with OSA are nonadherent.

View Article and Find Full Text PDF

Effects of Auto-Titrating Mandibular Advancement Device on Autonomic Nervous System in Obstructive Sleep Apnea.

J Pers Med

December 2024

Department of Otorhinolaryngology-Head and Neck Surgery, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon 24252, Republic of Korea.

One prior study revealed that a newly developed auto-titrating mandibular advancement device (AMAD) could potentially enhance polysomnographic outcomes in individuals with obstructive sleep apnea (OSA). However, evidence regarding its impact on autonomic nervous system dysregulation in OSA remains limited. In this study, we aimed to compare the effects of conventional mandibular advancement devices (MADs) and AMDA on autonomic function.

View Article and Find Full Text PDF

Obstructive sleep apnea syndrome (OSAS) is a frequently underdiagnosed sleep disorder marked by recurrent episodes of apnea and/or hypopnea during sleep, primarily resulting from the partial or complete collapse of the upper airway. OSAS significantly affects patients' health and quality of life. Additionally, it is a recognized risk factor for inducing microsleep episodes during daily activities, particularly in occupations such as professional driving, where sustained attention is critical.

View Article and Find Full Text PDF

Impact of CPAP Therapy on Cognition and Fatigue in Patients with Moderate to Severe Sleep Apnea: A Longitudinal Observational Study.

Clocks Sleep

December 2024

UR2NF-Neuropsychology and Functional Neuroimaging Research Unit, at CRCN-Centre for Research in Cognition and Neurosciences and UNI-ULB Neuroscience Institute, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium.

Continued solicitation of cognitive resources eventually leads to cognitive fatigue (CF), i.e., a decrease in cognitive efficiency that develops during sustained cognitive demands in conditions of constrained processing time, independently of sleepiness.

View Article and Find Full Text PDF

Total sleep time (TST) misperception has been reported in obstructive sleep apnea (OSA). However, previous findings on predictors were inconsistent and predominantly relied on single-night polysomnography, which may alter patients' sleep perception. We leveraged advances in wearable sleep staging to investigate predictors of TST misperception in OSA over multiple nights in the home environment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!