Some anesthesia machines indicate both analog and digital flow volumes of oxygen, air and nitrous oxide. We have noticed that there are discrepancies in the flows between analog and digital flow indicators of two anesthesia machine models (Dräger ; Fabius GS premium and Fabius Tiro). When oxygen or air flow is low, the analog indicator shows higher flows than the digital indicator. In contrast, when oxygen or air flow is high, the analog indicator shows lower flows than the digital indicator. This discrepancy is comparatively small when total gas flow is within the range of 2-5 l x min(-1). We contacted the manufacturer, which replied that the digital indicator is correct and the analog indicator should be regarded as an adjunctive, in case of a power failure when the digital indicator does not function. But this discrepancy may cause practical problems. When we cannot use a digital indicator and have to perform ventilation using a supporting gas cylinder, we may misjudge the available time for oxygen. In addition, when we use only analog indicator, insufficient volume of oxygen may be delivered, leading to the grave hypoxia.

Download full-text PDF

Source

Publication Analysis

Top Keywords

digital indicator
20
analog indicator
16
oxygen air
12
indicator
9
flow indicators
8
indicators anesthesia
8
analog digital
8
digital flow
8
air flow
8
flows digital
8

Similar Publications

Rationale: Thrombus is the most common occupying lesion in the cardiac chambers, it is often distinguished from cardiac neoplastic occupations. Among them, the most common is cardiac myxoma, whose imaging manifestations are often confused with thrombus. However, the 2 types of lesions have different therapeutic strategies and are both potentially high-risk sources of embolism, so early differentiation between intracardiac thrombus and cardiac tumor is essential.

View Article and Find Full Text PDF

Background: Sarcopenia is closely associated with a poor quality of life and mortality, and its prevention and treatment represent a critical area of research. Resistance training is an effective treatment for older adults with sarcopenia. However, they often face challenges when receiving traditional rehabilitation treatments at hospitals.

View Article and Find Full Text PDF

Surgical Scheduling Errors During Manual Data Transfer.

Qual Manag Health Care

January 2025

Author Affiliations: Source Healthcare, Santa Monica, California.

Background And Objectives: Retrospective studies examining errors within a surgical scheduling setting do not fully represent the effects of human error involved in transcribing critical patient health information (PHI). These errors can negatively impact patient care and reduce workplace efficiency due to insurance claim denials and potential sentinel events. Previous reports underscore the burden physicians face with prior authorizations which may lead to serious adverse events or the abandonment of treatment due to these delays.

View Article and Find Full Text PDF

Mold defects pose a significant risk to the preservation of valuable fine art paintings, typically arising from fungal growth in humid environments. This paper presents a novel approach for detecting and categorizing mold defects in fine art paintings. The technique leverages a feature extraction method called Derivative Level Thresholding to pinpoint suspicious regions within an image.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!