Purpose: The reduction of dose in cone beam computer tomography (CBCT) arises from the decrease of the tube current for each projection as well as from the reduction of the number of projections. In order to maintain good image quality, sophisticated image reconstruction techniques are required. The Prior Image Constrained Compressed Sensing (PICCS) incorporates prior images into the reconstruction algorithm and outperforms the widespread used Feldkamp-Davis-Kress-algorithm (FDK) when the number of projections is reduced. However, prior images that contain major variations are not appropriately considered so far in PICCS. We therefore propose the partial-PICCS (pPICCS) algorithm. This framework is a problem-specific extension of PICCS and enables the incorporation of the reliability of the prior images additionally.

Material And Methods: We assumed that the prior images are composed of areas with large and small deviations. Accordingly, a weighting matrix considered the assigned areas in the objective function. We applied our algorithm to the problem of image reconstruction from few views by simulations with a computer phantom as well as on clinical CBCT projections from a head-and-neck case. All prior images contained large local variations. The reconstructed images were compared to the reconstruction results by the FDK-algorithm, by Compressed Sensing (CS) and by PICCS. To show the gain of image quality we compared image details with the reference image and used quantitative metrics (root-mean-square error (RMSE), contrast-to-noise-ratio (CNR)).

Results: The pPICCS reconstruction framework yield images with substantially improved quality even when the number of projections was very small. The images contained less streaking, blurring and inaccurately reconstructed structures compared to the images reconstructed by FDK, CS and conventional PICCS. The increased image quality is also reflected in large RMSE differences.

Conclusions: We proposed a modification of the original PICCS algorithm. The pPICCS algorithm incorporates prior images as well as information about location dependent uncertainties of the prior images into the algorithm. The computer phantom and experimental data studies indicate the potential to lowering the radiation dose to the patient due to imaging while maintaining good image quality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.zemedi.2015.09.002DOI Listing

Publication Analysis

Top Keywords

prior images
28
image quality
16
compressed sensing
12
sensing piccs
12
number projections
12
images
11
image
10
prior
9
reliability prior
8
prior image
8

Similar Publications

Nasopharyngeal carcinoma (NPC) is an Epstein-Barr virus (EBV)-associated cancer, and immune checkpoint inhibitors (ICIs) have shown efficacy in its treatment. The combination of chemotherapy and ICIs represents a new trend in the standard care for metastatic NPC. In this study, we aim to clarify the immune cell profile and related prognostic factors in the ICI-based treatment of metastatic NPC.

View Article and Find Full Text PDF

Nontyphoidal is a common cause of gastroenteritis but can also lead to bacteremia and extraintestinal infections, including meningitis (more frequent in children and infants), endovascular infections (e.g., endocarditis and infected aneurysms), urinary tract infections, and bone or bone marrow infections (e.

View Article and Find Full Text PDF

Cryoglobulinemic vasculitis is a rare small-vessel vasculitis leading to multi-organ dysfunction, often associated with chronic infections like hepatitis C virus (HCV), and autoimmune disorders. Most cases involve mixed monoclonal or polyclonal immunoglobulins, presenting symptoms such as purpura, arthralgias, and weakness. Severe organ involvement, particularly cardiac, is rare but potentially life-threatening.

View Article and Find Full Text PDF

F-Florbetaben (FBB) uptake in the supratentorial cortex is indicative of amyloid positivity. Due to PET's low spatial resolution, image noise, and spill-over of signal from adjacent white-matter into gray-matter, there are inconsistencies in ratings among trained readers. A set of 264 F-Florbetaben (amyloid) PET/MRI exams were reconstructed using conventional ordered subset expectation maximization (OSEM) method and MR-guided block sequential regularized expectation maximization (MRgBSREM) method.

View Article and Find Full Text PDF

Primary central nervous system (CNS) lymphoma of the meninges is a rare tumor that originates in the meninges and does not show parenchymal or systemic spread. CNS involvement by natural killer (NK)/T-cell lymphoma accounts for only 2% of all extranodal NK/T-cell lymphomas, and primary NK/T-cell lymphoma of the meninges is even rarer. The present study reports a case of a 55-year-old male patient with primary NK/T-cell lymphoma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!