Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Recently updated recommendations for diagnosis of HIV infection suggest a new diagnostic algorithm including HIV-1/HIV-2 antibody differentiation immunoassay instead of western blot (WB) as a confirmatory testing. We evaluated Bio-Rad Geenius HIV1/2 confirmation assay as a simple and reliable alternative to WB in the Korean population with low HIV prevalence. The Geenius HIV1/2 was performed in a total of 192 serum specimens (140 reactive and 52 nonreactive specimens by ARCHITECT HIV Ag/Ab Combo assay) that were prospectively collected from five institutions. HIV-1 nucleic acid amplification test (NAT) was performed in negative or indeterminate specimens by Geenius HIV1/2 or WB. Among 140 reactive specimens by HIV Ag/Ab assay, 82 (58.6%) were positive for HIV-1 Ab by Geenius HIV1/2. Among 58 negative or indeterminate specimens by Geenius HIV1/2, four specimens (6.9%) were positive by HIV-1 NAT. The sensitivity and specificity of Geenius HIV1/2 were 95.3% and 100.0%, respectively. When we considered only WB, the sensitivity and specificity of Geenius HIV1/2 were 100.0% and 99.1%, respectively. Agreement between Geenius HIV1/2 and WB was excellent (weighted Kappa = 0.89). The Geenius HIV1/2 is simple and time-saving compared with WB. It has an excellent performance and can be a reliable alternative to WB. HIV-1 NAT should be performed in negative or indeterminate specimens by Geenius HIV1/2 to detect acute HIV infection as recommended in new HIV testing algorithms.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4589337 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0139169 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!