Purpose: The purpose of this study was to dosimetrically compare 6- and 10-MV photon beam energies in high-risk prostate cancer patients of various body habitus using a volumetric modulated arc therapy (VMAT) radiation delivery technique. The objectives of the study were to evaluate whether dosimetric differences exist and to investigate whether differences are dependent on patient body habitus.

Methods And Materials: Forty patients with various body habitus who had previously received treatment to the prostate and pelvic lymph nodes with VMAT techniques were chosen. Patients were planned in the Pinnacle(3) treatment planning system with double or triple SmartArc plans with 6- and 10-MV photon energies. All patients were optimized with the same planning objectives and normalized such that 95% of the planning target volume (PTV) received the prescription dose. Patients were evaluated for PTV and organ at risk (OAR) parameters for the bladder, rectum, small bowel, penile bulb, and sigmoid colon. Metrics used for comparison were D2%, D98%, homogeneity, conformity, and dose falloff for the PTV and D(2%), D(mean), V(80%), V(60%), and V(40%) for OARs. Statistical differences were evaluated with a paired-sample Wilcoxon signed rank test with a significance level of .05.

Results: For the PTV, there were no statistically significant differences in D(mean), D(2cc), conformation number, and homogeneity index values, but the dose falloff parameters, R50 and R25, showed a median improvement of 6.7% (P<.01) and 6.2% (P<.01), respectively, with 10 MV. A correlation between patient anterior-posterior distance (d(AP)) and percentage reduction in R50 of 0.436% per centimeter (P<.01) was determined. For OARs, statistically significant reductions in dose metrics were found in the small bowel and bladder, but increases in the D(2cc) of 3.5% in the penile bulb (P<.01) and 0.2% in the rectum (P=.02) were shown with 10 MV. The use of 10 MV also demonstrated a statistically significant reduction in the total number of monitor units of 15.9% (P<.01) compared with 6 MV.

Conclusions: The study showed that 10 MV provides a faster dose falloff than 6 MV for patients whose prostate and pelvic lymph nodes are treated using a VMAT technique irrespective of body habitus; however, the improvement in dose falloff is dependent on body habitus and increases as the patient body habitus increases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prro.2015.06.012DOI Listing

Publication Analysis

Top Keywords

body habitus
12
photon beam
8
volumetric modulated
8
modulated arc
8
arc therapy
8
prostate cancer
8
10-mv photon
8
patients body
8
dose falloff
8
patients
5

Similar Publications

Revision quadriceps tendon repair: A case series and technique guide to a novel repair.

Trauma Case Rep

February 2025

Department of Orthopaedic Surgery and Sports Medicine, University at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Buffalo, NY 14203, United States of America.

Introduction: Revision quadriceps tendon repair is a challenging problem. In this four-case series, novel quadriceps tendon revision resulted in improved range of motion and durable repair for patients with recurrent rupture.

Methods: Our technique includes a combination of a running locked #5 FiberWire or 2 mm SutureTape suture placed through parallel medial, lateral, and central drill holes in the patella with running Krackow-type quadriceps tendon repair medially and laterally resulting in four strands, delivering the vastus medialis and medial quadriceps tendon to an anatomic repair at the superior pole of the patella, with 2 sutures passed centrally and 1 each passed medially and laterally and then tied.

View Article and Find Full Text PDF

Long-Term Islet Graft Functional Assessments in More than 500 Patients Undergoing Total Pancreatectomy with Intraportal Islet Autotransplantation.

J Am Coll Surg

January 2025

Departments of Surgery, University of Minnesota Medical School Department of Pediatrics, University of Minnesota Medical School Division of Biostatistics and Health Data Science, School of Public Health, University of Minnesota.

Background: Total pancreatectomy and intraportal islet cell auto transplantation (TPIAT) is increasingly being offered to patients with refractory chronic pancreatitis. Understanding factors that impact islet function over time is critical.

Study Design: We evaluated factors associated with islet function over 12 years post TPIAT using mixed meal tolerance testing (MMTT).

View Article and Find Full Text PDF

Background: The main technique for identification of free flap perforator vessels is Doppler sonography, which is not always accurate, user dependent and affected by the patient's body habitus.

Methods: Adult patients undergoing head and neck resection and free flap reconstruction at two academic institutions were enrolled. Doppler sonography was used to identify perforators, and were marked using a skin marker.

View Article and Find Full Text PDF

Background & Aim: Sternotomy remains a commonly used technique to access the heart for cardiac surgery worldwide. To date, there is no clear consensus on the single superior sternal closure technique. Patient-specific factors such as osteoporosis, diabetes, old age, body habitus influence a surgeon's choice in this matter as do techniques commonly used during the training period and used in the current workplace.

View Article and Find Full Text PDF

Solenogastres is a group of mollusks with evolutionary and ecological importance. Nevertheless, their diversity is underestimated and knowledge about the distribution of the approximately 300 formally described species is limited. Factors that contribute to this include their small size and frequent misidentification by non-specialists.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!