Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Increased hemodynamic stress on vein grafts used in the arterial system is associated with vein graft disease. We determined whether a novel biodegradable external mesh stent could inhibit medial-intimal hyperplasia by suppressing hemodynamic stress on vein grafts and improve long-term patency.
Methods: Twenty-four beagles underwent bilateral femoral interposition grafting using reversed femoral veins. Vein grafts were externally supported by a novel poly L-lactide-ε-caprolactone copolymer (P(LA/CL)) biodegradable mesh stent or a nonabsorbable mesh stent. Vein grafts with no reinforcement were used as controls. The grafts were harvested 6 and 12 months after implantation for morphometric and immunohistochemical assessment.
Results: The endoluminal circumferential vein graft length was smaller in the P(LA/CL) and nonabsorbable groups (17.2 ± 2.9 and 19.0 ± 0.3 mm, respectively), than that in the control group (25.0 ± 2.6 mm, P < 0.01) at 12 months. The mean intimal-medial thickness was thinner in P(LA/CL) and nonabsorbable stent groups (0.18 ± 0.05 and 0.16 ± 0.05 mm, respectively), than that in the control group (0.30 ± 0.08 mm, P < 0.01). Differences in the intimal-medial thickness among the groups were associated with the magnitude of cellular proliferating activity. The graft patency ratio (100 %) was higher in the P(LA/CL) group than that in the nonabsorbable and control groups (72.2 and 63.6%, respectively, P < 0.05).
Conclusions: The biodegradable P(LA/CL) external mesh stent improved vein graft patency for 12 months and prevented vein graft dilatation and intimal hyperplasia associated with suppressed neointimal layer cellular proliferating activity.