Background: Endovascular aneurysm sealing (EVAS) using the Nellix system is a promising technology for Abdominal Aortic Aneurysm (AAA) treatment. Long-term data is unavailable regarding the potential modifications of the EndoBags and their content, and the polymer behavior over time. We present our initial clinical experience with this sac anchoring endoprosthesis in 24 patients with a maximum 12 months follow-up.

Methods: From December 2013 to March 2015, 24 patients with an infrarenal AAA were treated with the Nellix™ System. Computed tomography angiography (CTA) scan control was performed at 30 days, and follow-up magnetic resonance angiography (MRA) and ultrasounds were performed at 30 days, 6 and 12 months. Median and peak systolic velocities in the suprarenal aorta were measured preoperatively and during follow-up using phase contrast sequences and Argus (Siemens, Erlangen, Germany) software of the MRA.

Results: We achieved 100% technical success, 0% aneurysm-related mortality and 0% endoleaks. One patient (4%) experienced early acute thrombosis of a single Nellix stent, successfully treated with thrombolysis. Sac shrinkage occurred in 80% of cases with 12-months follow-up.

Conclusions: Our preliminary clinical experience is promising, with 100% early technical success and satisfactory sealing of the aneurysm sac. Postprocedural controls during 1-year follow-up revealed no morphologic changes of the aneurysm wall, stable device and endobag position, and gradual dissolution of the air initially trapped within the EndoBags. Aneurysmal sac shrinkage occurs and probably is due to the remodeling of the thrombus around the EndoBags and the dissipation of the air bubbles into the EndoBags.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S0021-9509.17.08920-0DOI Listing

Publication Analysis

Top Keywords

endovascular aneurysm
8
aneurysm sealing
8
sealing evas
8
patients infrarenal
8
abdominal aortic
8
clinical experience
8
performed days
8
technical success
8
sac shrinkage
8
aneurysm
5

Similar Publications

Patients with intracranial aneurysm (IA) are at high risk of cerebral hemorrhage, which is associated with high mortality. Craniotomy or interventional endovascular coiling are common treatment methods in clinical practice, depending on the patient's condition. However, the recurrence rate of IA after either method remains unclear.

View Article and Find Full Text PDF

The p48 MW HPC is a novel low-profile flow diverter covered by a hydrophilic polymer coating with antithrombogenic properties, which may reduce ischemic complications and enable a single antiplatelet therapy after insertion of the stent. In this single-center experience, we describe the efficacy of this device, focusing on the illustration of different therapeutic indications and the outcome in various clinical settings with regard to vessel anatomy, bleeding state, and aneurysm configuration. We retrospectively reviewed our database for all patients being treated with a p48 MW HPC flow diverter between February 2019 and July 2021.

View Article and Find Full Text PDF

Management of Anterior Choroidal Artery Aneurysms: A Retrospective Cohort Study.

Brain Sci

December 2024

Division of Neurointerventional Radiology, UMass-Chan Lahey Department of Radiology, Lahey Hospital and Medical Centre-Beth Israel Lahey Health, Burlington, MA 01805, USA.

Anterior choroidal artery (AChoA) aneurysms pose a challenge for both endovascular and clipping procedures. The eloquent territory supplied by the parent vessel has limited collateralization and its compromise can lead to significant morbidity. This study aims to analyze the clinical outcomes and procedure-related complications of clipping and endovascular treatment of AChoA aneurysms to aid physician decision making.

View Article and Find Full Text PDF

Purpose: To report a case series on using a novel semi-branch feature in custom-made stent-grafts in the endovascular treatment of complex aortic aneurysms and summarize the contemporary usage of this technology.

Case Series: Four patients underwent endovascular aortic aneurysm repair (EVAR) with a custom-made semi-branch stent-graft (Semi-Branch Endovascular Aortic Aneurysm Repair [SBEVAR]). Two male patients, 75- and 76-year-old, were treated due to failed EVAR with late-type Ia endoleak, and the other two, 80- and 55-year-old male patients, due to a juxta-renal aortic abdominal aneurysm (JRAAA).

View Article and Find Full Text PDF

Multiple Aneurysmal Arterial Disease (MAD) is an extremely rare arterial vascular condition and is produced by an abnormal alteration of smooth muscle cells and neutrophils, producing a multiple-aneurysmal degeneration. We present the case of a 36-year-old patient with a MAD in the cerebral territory and extremities with no surgical indication; however, with an aneurysm of the right inferior renal segmental artery, inferior mesenteric artery, left common iliac artery, and right internal iliac artery with surgical indication. An open approach with single-stage surgical repair, including graft interposition, bypass, exclusion, and vascular reimplantation, was performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!