A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reduction of distortion in photothermal microscopy and its application to the high-resolution three-dimensional imaging of nonfluorescent tissues. | LitMetric

Reduction of distortion in photothermal microscopy and its application to the high-resolution three-dimensional imaging of nonfluorescent tissues.

Biomed Opt Express

Advanced Ultrafast Laser Research Center, The University of Electro-Communications, 1-5-1 Chofugaoka, Chofu, Tokyo, 182-8585, Japan ; JST, CREST, K' Gobancho, 7, Gobancho, Chiyoda-ku, Tokyo 102-0076, Japan ; Department of Electrophysics, National Chiao-Tung University, Hsinchu 300, Taiwan ; Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0971, Japan.

Published: September 2015

A scheme for reducing image distortion in photothermal microscopy is presented. In photothermal microscopy, the signal shape exhibits twin peaks corresponding to the focusing or defocusing of the probe beam when a sample is scanned in the axial direction. This causes a distortion when imaging a structured sample in the axial plane. Here, we demonstrate that image distortion caused by the twin peaks is effectively suppressed by providing a small offset between two the focal planes of the pump and the probe beams. Experimental results demonstrate improvement in resolution, especially in the axial direction, over conventional optical microscopy-even with the focal offset. When a dry objective lens with a numerical aperture of 0.95 is used, the full width at half the maximum of the axial point spread function is 0.6 μm, which is 50% (62%) smaller than the focal spot sizes of the pump (probe) beam. Herein, we present high-resolution three-dimensional imaging of thick biological tissues based on the present scheme.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4574650PMC
http://dx.doi.org/10.1364/BOE.6.003217DOI Listing

Publication Analysis

Top Keywords

photothermal microscopy
12
distortion photothermal
8
high-resolution three-dimensional
8
three-dimensional imaging
8
image distortion
8
twin peaks
8
probe beam
8
axial direction
8
pump probe
8
reduction distortion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!