The anesthesiologist is frequently involved in the task of achieving central venous access either for intraoperative uses or postoperative purposes or Intensive Care Unit care. We are usually aware of the common complications of subclavian approach, such as arterial puncture, bleeding, pneumothorax, misplacement in the ipsilateral internal jugular vein (IJV) or contralateral brachiocephalic or subclavian vein. In this case report, we highlight the possibility of malpositioning of central venous cannula inserted through IJV into the anterior extra pleural plane after failed subclavian cannulation attempts.