Statement Of Problem: The use of monolithic zirconia crowns in implant prostheses is increasing, especially when the interdental space is insufficient. However, fractures have been reported in clinical practice.

Purpose: The purpose of this study was to determine the minimal thickness of a complete zirconia crown used for an implant prosthesis in the posterior dental region.

Material And Methods: Fifty complete zirconia crowns were produced using a computer-aided design/computer-aided manufacturing technique. In each group, 5 crowns of varying thicknesses (0.4, 0.5, 0.6, 0.7, and 0.8 mm) were subjected to cycles of vertical and 10-degree oblique compressive loading at 5 Hz and 300 N in a servohydraulic testing machine. Five finite element models comprising 5 different occlusal thicknesses (0.4, 0.5, 0.6, 0.7, and 0.8 mm) were simulated at 2 loading angles (0 and 10 degrees) and 3 loading forces (300, 500, and 800 N). Data were statistically analyzed, and fracture patterns were observed with a scanning electron microscope.

Results: Cyclic loading tests revealed that the fracture resistance of the specimens was positively associated with prosthesis thickness (P<.01). Low von Mises stress values were obtained for prostheses with a minimal thickness of 0.7 mm under varying loading directions and forces.

Conclusions: Zirconia prostheses with a minimal thickness of 0.7 mm had a high fracture resistance and the lowest stress values. Therefore, dentists and laboratory technicians should carefully choose the optimum thickness of zirconia prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2015.06.021DOI Listing

Publication Analysis

Top Keywords

zirconia crowns
12
fracture resistance
8
monolithic zirconia
8
occlusal thicknesses
8
implant prostheses
8
complete zirconia
8
resistance monolithic
4
zirconia
4
crowns
4
crowns occlusal
4

Similar Publications

A cross-sectional study on improving clinical efficiency through centralized digital impression.

Hua Xi Kou Qiang Yi Xue Za Zhi

February 2025

Center of Stomatology, Peking University Shenzhen Hospital, Shenzhen 518036, China.

Objectives: This study aims to explore the effect of improving clinical efficiency by replacing traditional impression workflow with centralized digital impression workflow.

Methods: The department of prosthodontics in Center of Stomatology, Peking University Shenzhen Hospital has improved the clinical workflow by replacing the traditional impression made by doctors using impression materials for each patient with a centralized digital impression made by one technician for all patients in the department. This cross-sectional study recorded the chairside time required for impression taking in patients undergoing single posterior zirconia full crown restoration before clinical process improvement; the time required for centralized digital impression production; the comfort level of patients; and the adjacency relationship, occlusal contact relationship, and time required for prostheses adjusting (i.

View Article and Find Full Text PDF

This study aims to investigate the effects of material compatibility, variable cooling rates, and crown geometry on thermal stress development in porcelain-veneered lithium disilicate (PVLD) and porcelain-veneered zirconia (PVZ) dental crown systems, and subsequently anticipate parameters for their optimum performance. An anatomically correct 3D crown model was developed from STL files generated using 3D scans of the experimental crown sample. Next, the viscoelastic finite element model (VFEM) based on the 3D crown model was developed and validated for anatomically correct bilayer PVLD and PVZ crown systems.

View Article and Find Full Text PDF

This study numerically investigates the impact of different loading modes on the biomechanical response of an osseointegrated dental implant. While finite element modeling is commonly employed to investigate the mechanical behavior of dental implants, several models lack physiological accuracy in their loading conditions, omitting occlusal contact points that influence stress distribution in periimplant bone. Using 3D finite element modeling and analysis, stress distributions at the bone-implant interface are evaluated under both physiological loading, incorporating natural occlusal contact points, and non-physiological loading conditions, with a focus on load transmission mechanisms and the potential risk of bone overloading.

View Article and Find Full Text PDF

This study evaluated the effect of substrate core materials and occlusal contact patterns on the fatigue mechanical behavior and stress distribution of single-unit ceramic crowns. One hundred and twenty monolithic crowns were fabricated from zirconia (YZ - IPS e.max ZirCAD, Ivoclar), lithium disilicate (LD - IPS e.

View Article and Find Full Text PDF

Surgical treatment for severe endodontic-periodontal lesion: A case report with 2-year follow-up.

Clin Adv Periodontics

January 2025

Department of Periodontology, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.

Background: Various surgical techniques have recently been developed for periodontal tissue regeneration, especially those do not involve any incisions in the interdental papillae at the regeneration site. These techniques have significant advantages for obtaining clinical attachment gain with least amount of gingival recession, however, may also have disadvantages such as limited field of surgical view, difficulty in debridement, and limited access only from the buccal side. This case report addresses a 2-year follow-up with a novel surgical approach to achieve periodontal regeneration that overcomes these limitations: the flexible tunnel technique (FTT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!