A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characteristic X-ray absorptiometry applied to the assessment of tissue-engineered cartilage development. | LitMetric

Background: Transmission and tomographic X-ray measurements are useful in assessing bone structures, but only a few studies have examined cartilage growth because of the poor contrast in conventional X-ray imaging.

Objective: In this study, we attempted to use the linear attenuation coefficient (LAC) as a metric of tissue-engineered cartilage development, which would be useful in high-throughput screening of cartilage products.

Methods: Assuming that the LAC is related to the amount of extracellular matrix (ECM) in terms of the density and its atomic components, we measured X-ray absorption through tissue-engineered cartilage constructs. Characteristic X-ray beams from a molybdenum microfocus X-ray tube were employed to avoid beam hardening. The correlation of the LAC with mechanical properties was analyzed for verification.

Results: The LAC was higher for chondrocyte constructs and lower for fibroblast-dominant constructs and was consistent with the quantification of toluidine blue staining, which is a proof of ECM production. The LAC was positively correlated with the bending modulus but negatively correlated with the dynamic elastic modulus and stiffness, possibly because of the remaining scaffold.

Conclusions: The LAC has the potential to be used as a metric of development of tissue-engineered cartilage. However, the calcified regions should be excluded from analysis to avoid decreasing the correlation between the LAC and the amount of ECM.

Download full-text PDF

Source
http://dx.doi.org/10.3233/XST-150504DOI Listing

Publication Analysis

Top Keywords

tissue-engineered cartilage
16
characteristic x-ray
8
cartilage development
8
lac amount
8
correlation lac
8
lac
7
cartilage
6
x-ray
5
x-ray absorptiometry
4
absorptiometry applied
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!