Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Advances in cardiopulmonary bypass equipment have played a critical role in improving outcomes for cardiac surgery patients. Recent advancements include reduced priming volumes, biocompatible coatings and gaseous microemboli handling, as well as the incorporation of an arterial filter into the oxygenator.The purpose of this study was to conduct a comprehensive clinical evaluation of adult oxygenators on the market. Oxygenators assessed included the Sorin Synthesis(®) (n = 30), the Sorin Inspire 6F(®) (n = 10) and Inspire 8F(®) (n = 30), the Terumo FX15(®) (n = 13) and FX25(®) (n = 30), the Maquet Quadrox-i(®) (n = 30) and the Medtronic Fusion(®) (n = 30). Parameters assessed included functional prime volumes, gas exchange, pressure gradients and the effects on patient hematology.The Synthesis had the largest functional prime volume (1426 ml), the FX15 the lowest (956 ml). The Inspire 6F, 8F and Fusion had the greatest O2 transfer. The Sorin oxygenators required the lowest sweep gas flows to obtain a PaCO2 of 40 mmHg. The Sorin oxygenators had the largest pressure gradients. While no differences were observed for hemoglobin and platelet levels post cross-clamp removal, the Sorin Synthesis and Inspire 8F had the largest increases in white blood cell (WBC) counts (122% and 141% of baseline, respectively) and neutrophils (162% and 185% of baseline, respectively).The data demonstrate that no single product is superior in all aspects. The choice of ideal oxygenator depends on the aspect(s) of oxygenator performance the perfusion team believes most clinically acceptable based on available data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0267659115604709 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!