A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A plasma-sprayed titanium proximal coating reduces the risk of periprosthetic femoral fracture in cementless hip arthroplasty. | LitMetric

Background: The design of femoral component used in total hip arthroplasty is known to influence the incidence of periprosthetic femoral fractures (PFFs) in cementless hip arthroplasty.

Objective: This study was undertaken to determine if 2 potential changes to an existing ABG II-standard cementless implant - addition of a roughened titanium plasma-sprayed proximal coating (ABG II-plasma) and lack of medial scales (ABG II-NMS) could decrease the risk of PFF in the intraoperative and early postoperative periods.

Methods: Six pairs of human cadaveric femurs were harvested and divided into 2 groups, each receiving either of the altered implants and ABG II-standard (control). Each implant was tested in a biomechanical setup in a single-legged stance orientation. Surface strains were measured in intact femurs, during implant insertion, cyclic loading of the bone with the implant, and loading to failure. Strains with the ABG II-standard and the altered implants were compared.

Findings: ABG II-plasma showed better load-bearing capacity, with an average 42% greater failure load than that of ABG II-standard. The cortical hoop, axial and mean strains ABG II-plasma were less than those of ABG II-standard, demonstrating decreased tensile behaviour and better load transfer to the proximal femur. The final residual hoop strains in ABG II-plasma were closer to those of intact bone as compared to the standard stem. No differences in strains were observed between the standard stem and ABG II-NMS.

Conclusion: The increased load-bearing capacity and decreased proximal surface strains on femurs implanted with ABG II-plasma stem should reduce the risks of intraoperative and early postoperative PFF.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BME-151279DOI Listing

Publication Analysis

Top Keywords

abg ii-standard
20
abg ii-plasma
20
abg
12
strains abg
12
proximal coating
8
periprosthetic femoral
8
cementless hip
8
hip arthroplasty
8
intraoperative early
8
early postoperative
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!