A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Wireless charing pillow for a fully implantable hearing aid: Design of a circular array coil based on finite element analysis for reducing magnetic weak zones. | LitMetric

Many types of fully implantable hearing aids have been developed. Most of these devices are implanted behind the ear. To maintain the implanted device for a long period of time, a rechargeable battery and wireless power transmission are used. Because inductive coupling is the most renowned method for wireless power transmission, many types of fully implantable hearing aids are transcutaneously powered using inductively coupled coils. Some patients with an implantable hearing aid require a method for conveniently charging their hearing aid while they are resting or sleeping. To address this need, a wireless charging pillow has been developed that employs a circular array coil as one of its primary parts. In this device, all primary coils are simultaneously driven to maintain an effective charging area regardless of head motion. In this case, however, there may be a magnetic weak zone that cannot be charged at the specific secondary coil's location on the array coil. In this study, assuming that a maximum charging distance is 4 cm, a circular array coil-serving as a primary part of the charging pillow-was designed using finite element analysis. Based on experimental results, the proposed device can charge an implantable hearing aid without a magnetic weak zone within 4 cm of the perpendicular distance between the primary and secondary coils.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BME-151474DOI Listing

Publication Analysis

Top Keywords

implantable hearing
20
hearing aid
16
fully implantable
12
circular array
12
array coil
12
magnetic weak
12
finite element
8
element analysis
8
types fully
8
hearing aids
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!