Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI.

Biomed Mater Eng

Department of Biomedical Engineering, I-Shou University, No.8, Yida Rd., Jiaosu Village Yanchao District, Kaohsiung City, 82445, Taiwan, R.O.C.

Published: July 2016

Magnetic Resonance Imaging (MRI) has been one of the most revolutionary medical imaging modalities in the past three decades. It has been recognized as a potential technique in the clinical diagnosis of diseases as well as tumor differentiation. Although MRI has now become the preferred choice in many clinical examinations, there are some drawbacks, which still limit its applications. One of the crucial issues of MRI is the geometric distortion caused by magnetic field inhomogeneity and susceptibility effects. The farther the lesion from the center of a magnetic field (off-center field), the more severe the distortion becomes, especially in low-field MRI. Hence, it might hinder the diagnosis and characterization of lesions in the presence of field inhomogeneity. In this study, an innovative multi-orientated water-phantom was used to evaluate the geometric distortion. The correlations between the level of image distortion and the relative off-center positions, as well as the variation of signal intensities, were both investigated. The image distortion ratios of axial, coronal and sagittal images were calculated.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BME-151441DOI Listing

Publication Analysis

Top Keywords

geometric distortion
12
multi-orientated water-phantom
8
magnetic field
8
field inhomogeneity
8
image distortion
8
mri
5
distortion
5
distortion evaluation
4
evaluation multi-orientated
4
water-phantom mri
4

Similar Publications

Purpose: Although the lens undoubtedly plays a major role in presbyopia, altered lens function could be in part secondary to age-related changes of the ciliary muscle. Ciliary muscle changes with accommodation have been quantified using optical coherence tomography, but so far these studies have been limited to quantifying changes in ciliary muscle thickness, mostly at static accommodative states. Quantifying ciliary muscle thickness changes does not effectively capture the dynamic anterior-centripetal movement of the ciliary muscle during accommodation.

View Article and Find Full Text PDF

High selectivity, capacity and stability for electrochemical lithium extraction on boron-doped HMnO by tailoring lattice constant and intercalation energy.

Water Res

January 2025

State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, PR China; College of Environment and Resources, Xiangtan University, Xiangtan, Hunan 411105, PR China. Electronic address:

A sustainable supply of lithium from salt-lake brines is necessary due to the surge in demand of the lithium-battery market. However, the presence of coexisting ions, particularly Na, poses a significant challenge due to the similarities in charge, electronic structure, and hydrated size. The electrochemical system with manganese (Mn)-based lithium-ion (Li) sieves electrodes is a promising method for Li recovery, but often suffers from geometric configuration distortion, which reduces their selectivity and capacity.

View Article and Find Full Text PDF

Introduction The Synaptive magnetic resonance imaging (MRI) system (Synaptive Medical, Toronto, Canada) is a midfield 0.5 T head-only scanner for imaging the head and neck in adults and pediatrics. The system received US FDA and Health Canada clearance for clinical use in 2020.

View Article and Find Full Text PDF

Background: Diffusion-weighted (DW) turbo-spin-echo (TSE) imaging offers improved geometric fidelity compared to single-shot echo-planar-imaging (EPI). However, it suffers from low signal-to-noise ratio (SNR) and prolonged acquisition times, thereby restricting its applications in diagnosis and MRI-guided radiotherapy (MRgRT).

Purpose: To develop a joint k-b space reconstruction algorithm for concurrent reconstruction of DW-TSE images and the apparent diffusion coefficient (ADC) map with enhanced image quality and more accurate quantitative measurements.

View Article and Find Full Text PDF

The formation of following the double ionization of small organic compounds via a roaming mechanism, which involves the generation of H and subsequent proton abstraction, has recently garnered significant attention. Nonetheless, a cohesive model explaining trends in the yield of characterizing these unimolecular reactions is yet to be established. We report yield and femtosecond time-resolved measurements following the strong-field double ionization of CHX molecules, where X = OD, Cl, NCS, CN, SCN, and I.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!