Radiotherapy treatment plan may be replanned due the changes of tumors and organs at risk (OARs) during the treatment. Deformable image registration (DIR) based Computed Tomography (CT) contour propagation in the routine clinical setting is expected to reduce time needed for necessary manual tumors and OARs delineations and increase the efficiency of replanning. In this study, a DIR method was developed for CT contour propagation. Prior structure delineations were incorporated into Demons DIR, which was represented by adding an intensity matching term of the delineated tissues pairs to the energy function of Demons. The performance of our DIR was evaluated with five clinical head-and-neck and five lung cancer cases. The experimental results verified the improved accuracy of the proposed registration method compared with conventional registration and Demons DIR.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BME-151399DOI Listing

Publication Analysis

Top Keywords

contour propagation
12
deformable image
8
image registration
8
demons dir
8
dir
5
registration
4
registration images
4
images automatic
4
automatic contour
4
propagation radiation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!