Thrombelastography (TEG)/thromboelastometry (ROTEM) devices measure viscoelastic clot strength as clot amplitude (A). Transformation of clot amplitude into clot elasticity (E with TEG; CE with ROTEM) is sometimes necessary (eg, when calculating platelet component of the clot). With TEG, clot amplitude is commonly transformed into shear modulus (G; expressed in Pa or dyn/cm) as follows: G = (5000 × A)/(100 - A). Use of the constant "5000" stems from Hartert's 50-year-old calculation of G for a normal blood clot. We question the value of calculating G as follows: (1) It may be questioned whether TEG/ROTEM analysis enable measurement of elasticity because viscosity may also contribute to clot amplitude. (2) It has been suggested that absolute properties of a blood clot cannot be measured with TEG/ROTEM analysis because the strain amplitude applied by the device is uncontrolled and changes during the course of coagulation. (3) A review of the calculation of G using Hartert's methods and some updated assumptions suggests that the value of 5000 is unreliable. (4) Recalculation of G for the ROTEM device yields a different value from that with Hartert TEG, indicating a degree of inaccuracy with the calculations. (5) Shear modulus is simply a multiple of E/CE and, because of the unreliability of G in absolute terms, it provides no additional value versus E/CE. The TEG and ROTEM are valuable coagulation assessment tools that provide an evaluation of the viscoelastic properties of a clot, not through measuring absolute viscoelastic forces but through continuous reading of the clot amplitude relative to an arbitrary, preset scale.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5349316PMC
http://dx.doi.org/10.1177/1076029615606531DOI Listing

Publication Analysis

Top Keywords

clot amplitude
20
clot
11
teg rotem
8
shear modulus
8
blood clot
8
teg/rotem analysis
8
amplitude
6
revisiting hartert's
4
hartert's 1962
4
1962 calculation
4

Similar Publications

Background: Systemic infection (SCI) is the third most common cause of late-onset sepsis in Neonatal Intensive Care Units (NICU). While platelet involvement in fungal infections has been extensively studied, evaluation of the hemostatic mechanism in Candida infections, especially in neonates, has not been widely investigated. The aim of the current study was to evaluate the hemostatic profile of neonates with SCI through rotational thromboelastometry (ROTEM), a laboratory method that assesses the viscoelastic properties of blood.

View Article and Find Full Text PDF

Introduction: Platelet transfusion has been therapeutically used in patients with thrombocytopenia and platelet function defects over the years. The use of advanced techniques may add value in assessing the quality of platelet products. The aim of the study was to assess stored platelet concentrates (PCs) prepared in blood banks for platelet indices, clot strength, and platelet function.

View Article and Find Full Text PDF

Thromboelastography may assess the effect of anticoagulation reversal in intracranial hemorrhage.

J Stroke Cerebrovasc Dis

January 2025

Department of Neurology, University of Iowa College of Medicine, United States; Department of Epidemiology, University of Iowa College of Public Health, United States; Department of Neurosurgery, University of Iowa College of Medicine, United States.

Article Synopsis
  • Intracranial hemorrhage (ICH) is a serious risk for patients on oral anticoagulants, and there's a need for biomarkers to evaluate the effectiveness of reversal agents like activated prothrombin complex concentrate (aPCC).
  • A study was conducted in an emergency department with adult patients experiencing factor Xa inhibitor-related ICH to assess changes in thromboelastography (TEG) following aPCC reversal.
  • Results showed a significant decrease in TEG R-time shortly after aPCC administration, but it returned to baseline levels by 12 and 24 hours, suggesting TEG R-time could be a valuable biomarker to monitor anticoagulation effects in these patients.
View Article and Find Full Text PDF

Evaluation of a Point-of-Care-Viscoelastic Coagulation Device in Hispaniolan Amazon Parrots ().

J Avian Med Surg

January 2025

Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA.

Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.

View Article and Find Full Text PDF

Background And Objectives: The most widely used method of platelet cryopreservation requires the addition of 5%-6% dimethylsulphoxide (DMSO), followed by its pre-freeze removal via centrifugation, to minimize toxicity. However, this adds complexity to the pre-freeze and post-thaw processing. Accordingly, the aim of this study was to simplify platelet cryopreservation by reducing the DMSO concentration and omitting the requirement for pre-transfusion removal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!