Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

Pacing Clin Electrophysiol

Pediatric Arrhythmia Service, Division of Pediatric Cardiology, Department of Pediatrics, The Children's Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, New York.

Published: December 2015

Purpose: To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs).

Methods: A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups.

Results: Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time.

Conclusions: Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.12742DOI Listing

Publication Analysis

Top Keywords

three-catheter technique
8
ablation
8
ablation left-sided
8
accessory pathways
8
efficacy safety
8
conventional five-catheter
8
five-catheter approach
8
wpw concealed
8
three-catheter group
8
three-catheter
6

Similar Publications

Introduction: Pulmonary vein isolation (PVI) is a pivotal part of ablative therapy for atrial fibrillation (AF). Currently, there are multiple techniques available to realize PVI, including: manual-guided cryoballoon (MAN-CB), manual-guided radiofrequency (MAN-RF), and robotic magnetic navigation-guided radiofrequency ablation (RMN-RF). There is a lack of large prospective trials comparing contemporary RMN-RF with the more conventional ablation techniques.

View Article and Find Full Text PDF

Objective: Deep vein thrombosis is a common and serious complication associated with midline catheters (MC). The aim of this investigation was to determine if catheter diameter is related to development of thrombosis.

Methods: This was an observational cohort study conducted at a tertiary care academic center in Southeastern Michigan.

View Article and Find Full Text PDF

Low-energy (360 J) radiofrequency catheter ablation using moderate power - short duration: proof of concept based on in silico modeling.

J Interv Card Electrophysiol

August 2023

Division of Cardiovascular Medicine, Harvard-Thorndike Electrophysiology Institute, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, 02215, USA.

Background: Pilot clinical studies suggest that very high power-very short duration (vHPvSD, 90 W/4 s, 360 J energy) is a feasible and safe technique for ablation of atrial fibrillation (AF), compared with standard applications using moderate power-moderate duration (30 W/30 s, 900 J energy). However, it is unclear whether alternate power and duration settings for the delivery of the same total energy would result in similar lesion formation. This study compares temperature dynamics and lesion size at different power-duration settings for the delivery of equivalent total energy (360 J).

View Article and Find Full Text PDF

Clinicians are required to manage a growing number of elderly patients with several medical comorbidities, and invasive surgical treatments are sometimes not advisable for these patients. The aim of this study was to evaluate the efficacy of minimally invasive intraspinal canal treatment, trans-sacral canal plasty (TSCP), for patients with and without failed back surgery syndrome (FBSS). A multicenter analysis was conducted.

View Article and Find Full Text PDF

Catheter ablation of paroxysmal atrial fibrillation (PAF) has been shown to be effective and safe. However, recurrence of PAF varies between 10 and 30% for radiofrequency ablation. There have been no reports comparing long-term recurrence rates following radiofrequency ablation, cryoablation, and three-dimensional guided cryoablation plus radiofrequency ablation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!