SADMFR Guidelines for the Use of Cone-Beam Computed Tomography/Digital Volume Tomography.

Swiss Dent J

Section of Dental Radiology and Stomatology, Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern, Switzerland.

Published: January 2015

In 2011, the first consensus conference on guidelines for the use of cone-beam computed tomography (CBCT) was convened by the Swiss Society of Dentomaxillofacial Radiology (SGDMFR). This conference covered topics of oral and maxillofacial surgery, temporomandibular joint dysfunctions and disorders, and orthodontics. In 2014, a second consensus conference was convened on guidelines for the use of CBCT in endodontics, periodontology, reconstructive dentistry and pediatric dentistry. The guidelines are intended for all dentists in order to facilitate the decision as to when the use of CBCT is justified. As a rule, the use of CBCT is considered restrictive, since radiation protection reasons do not allow its routine use. CBCT should therefore be reserved for complex cases where its application can be expected to provide further information that is relevant to the choice of therapy. In periodontology, sufficient information is usually available from clinical examination and periapical radiographs; in endodontics alternative methods can often be used instead of CBCT; and for implant patients undergoing reconstructive dentistry, CT is of interest for the workflow from implant planning to the superstructure. For pediatric dentistry no application of CBCT is seen for caries diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.61872/sdj-2015-09-01DOI Listing

Publication Analysis

Top Keywords

guidelines cone-beam
8
cone-beam computed
8
consensus conference
8
reconstructive dentistry
8
pediatric dentistry
8
cbct
7
sadmfr guidelines
4
computed tomography/digital
4
tomography/digital volume
4
volume tomography
4

Similar Publications

Evaluation of maxillary sinus pathologies and the posterior superior alveolar artery canal using cone-beam computed tomography.

BMC Oral Health

January 2025

Department of Oral and Maxillofacial Surgery, Ahmet Kelesoglu Faculty of Dentistry, Karaman, 70200, Türkiye.

Objective: This study aims to determine the anatomical relationship between the posterior superior alveolar artery (PSAA) and the lateral wall of the maxillary sinus during preoperative radiological evaluations in the posterior maxillary dental region, as well as to evaluate the prevalence of PSAA and its potential associations with sinus pathologies.

Materials And Methods: This retrospective study is based on the analysis of Cone-Beam Computed Tomography (CBCT) data from 510 sinuses of 255 patients. The visibility of the PSAA vascular canal, artery diameters, vertical distance between the alveolar crest and the artery, and the distance to the sinus floor were measured in coronal sections.

View Article and Find Full Text PDF

Background: A comprehensive analysis of the occlusal plane (OP) inclination in predicting anteroposterior mandibular position (APMP) changes is still lacking. This study aimed to analyse the relationships between inclinations of different OPs and APMP metrics and explore the feasibility of OP inclination in predicting changes in APMP.

Methods: Overall, 115 three-dimensional (3D) models were reconstructed using deep learning-based cone-beam computed tomography (CBCT) segmentation, and their accuracy in supporting cusps was compared with that of intraoral scanning models.

View Article and Find Full Text PDF

Accuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study.

Int J Implant Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China.

Purpose: This study evaluated the accuracy of implant placement using a robotic system (Remebot) compared to freehand surgery and explored factors influencing accuracy.

Methods: This retrospective study included 95 implants placed in 65 patients, divided into robot-assisted (50 implants) and freehand (45 implants) groups. Platform, apical, and angular deviations were measured by superimposing preoperative plans and the postoperative CBCT images.

View Article and Find Full Text PDF

A novel classification system, termed the Sivan classification, was developed to enhance the diagnosis of jaw lesions by utilizing visual volumetric analysis of three-dimensional Cone Beam Computed Tomography (CBCT) images. This classification groups lesions into ten categories, primarily divided into hypovolumetric, hypervolumetric, and normovolumetric groups. To validate this system, 10 raters-comprising 5 general dentists and 5 oral radiology specialists-assessed the CBCT images and diagnosed the lesions using the Sivan classification.

View Article and Find Full Text PDF

Background: This study aims to evaluate the impact of different thresholds and voxel sizes on the accuracy of Cone-beam computed tomography (CBCT) tooth reconstruction and to assess the accuracy of fused CBCT and intraoral scanning (IOS) tooth models using curvature continuity algorithms under varying thresholds and voxel conditions.

Methods: Thirty-two isolated teeth were digitized using IOS and CBCT at two voxel sizes and five threshold settings. Crown-root fusion was performed using a curvature continuity algorithm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!