Objective: The objective of this study was to determine the accuracy of renal measurement on CT in multiple imaging planes.

Materials And Methods: In this study, three board-certified radiologists retrospectively measured 110 kidneys on CT in 55 consecutive patients. Five measurement methods were used: axial, coronal single image, coronal multiimage, sagittal single image, and sagittal multiimage. The coronal database was sent to a postprocessing workstation, and each radiologist performed a maximum renal measurement using a best off-axis plane that was our reference standard. An ANOVA test with repeated measures and posthoc Bonferroni corrected t tests were performed.

Results: The mean differences (± standard error) compared with the reference standard method were as follows: axial, 7.7 ± 0.7 mm; coronal single image, 13.1 ± 1.4 mm; coronal multiimage, 6.4 ± 0.8 mm; sagittal single image, 6.4 ± 0.6 mm; and sagittal multiimage, 2.8 ± 0.3 mm. The reference standard measurement was larger (p < 0.001), whereas the coronal single-image measurement (p ≤ 0.006) was smaller than all other methods. The sagittal multiimage (p ≤ 0.005) was statistically significantly different from all other methods. There were no statistically significant differences among the axial, coronal multiimage, and sagittal single-image methods (p ≥ 0.088).

Conclusion: The single-image coronal method is the least accurate, with an error of approximately 13 mm. The axial, multiimage coronal, and single-image sagittal methods underestimate renal size by approximately 6-8 mm. Multiimage sagittal is the most accurate method for measuring kidneys with an error of approximately 3 mm.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.14.14248DOI Listing

Publication Analysis

Top Keywords

single image
16
multiimage sagittal
16
axial coronal
12
coronal multiimage
12
sagittal multiimage
12
reference standard
12
coronal
9
renal measurement
8
coronal single
8
multiimage
8

Similar Publications

Background: There are insufficient studies to determine whether sodium-glucose cotransporter type 2 inhibitors (SGLT2i) will help reduce early diabetic cardiomyopathy, especially in patients without documented cardiovascular disease.

Methods: We performed a single center, prospective observation study. A total of 90 patients with type 2 diabetes patients without established heart failure or atherosclerotic cardiovascular disease were enrolled.

View Article and Find Full Text PDF

Supervised machine learning statistical models for visual outcome prediction in macular hole surgery: a single-surgeon, standardized surgery study.

Int J Retina Vitreous

January 2025

Department of Retina and Vitreous, Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, India.

Purpose: To evaluate the predictive accuracy of various machine learning (ML) statistical models in forecasting postoperative visual acuity (VA) outcomes following macular hole (MH) surgery using preoperative optical coherence tomography (OCT) parameters.

Methods: This retrospective study included 158 eyes (151 patients) with full-thickness MHs treated between 2017 and 2023 by the same surgeon and using the same intraoperative surgical technique. Data from electronic medical records and OCT scans were extracted, with OCT-derived qualitative and quantitative MH characteristics recorded.

View Article and Find Full Text PDF

Background: Total laparoscopic hysterectomy (TLH) is nowadays the standard to treat benign and malignant disease occurring in the uterus, but the number of robotic-assisted surgeries is increasing worldwide. To facilitate the handling of sutures in a bi- and tri-dimensional plane, a new type of suture material has been developed, named barbed sutures, which are in use in different indications. In comparison to conventional suture materials, the barbs anchor the suture in the tissue, provide tissue approximation and prevent slippage without the need for knot tying.

View Article and Find Full Text PDF

The emerging combination of chemotherapy and radionuclide therapy has been actively investigated to overcome the limitations of monotherapy and augment therapeutic efficacy. However, it remains a challenge to design a single delivery vehicle that can incorporate chemotherapeutics and radionuclides into a compact structure. Here, a chelator DOTA- or NOTA-modified Evans blue conjugated camptothecin molecule (EB-CPT) nanoprodrug was synthesized, which could self-assemble into nanoparticles due to its inherent amphiphilicity.

View Article and Find Full Text PDF

The use of photoacoustic brain imaging for hemorrhage detection holds significant clinical importance. This study focuses on the performance of sensitivity and detection capabilities of a single-element scanning system, considering the remarkable signal-to-noise ratio of photoacoustic signals generated by a single-element transducer. By employing blood vessel-like phantoms and ex vivo brain phantoms, we demonstrated the superior efficacy of the single-element scanning method over the transducer array system in the context of brain hemorrhage detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!