Magnetic resonance imaging and spectroscopy of hyperpolarized (HP) compounds such as [1-(13)C]-pyruvate have shown tremendous potential for offering new insight into disease and response to therapy. New applications of this technology in clinical research and care will require extensive validation in cells and animal models, a process that may be limited by the high cost and modest throughput associated with dynamic nuclear polarization. Relatively wide spectral separation between [1-(13)C]-pyruvate and its chemical endpoints in vivo are conducive to simultaneous multi-sample measurements, even in the presence of a suboptimal global shim. Multi-channel acquisitions could conserve costs and accelerate experiments by allowing acquisition from multiple independent samples following a single dissolution. Unfortunately, many existing preclinical MRI systems are equipped with only a single channel for broadband acquisitions. In this work, we examine the feasibility of this concept using a broadband multi-channel digital receiver extension and detector arrays that allow concurrent measurement of dynamic spectroscopic data from ex vivo enzyme phantoms, in vitro anaplastic thyroid carcinoma cells, and in vivo in tumor-bearing mice. Throughput and the cost of consumables were improved by up to a factor of four. These preliminary results demonstrate the potential for efficient multi-sample studies employing hyperpolarized agents.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628838PMC
http://dx.doi.org/10.1016/j.jmr.2015.08.025DOI Listing

Publication Analysis

Top Keywords

high-throughput hyperpolarized
4
hyperpolarized 13c
4
13c metabolic
4
metabolic investigations
4
investigations multi-channel
4
multi-channel acquisition
4
acquisition system
4
system magnetic
4
magnetic resonance
4
resonance imaging
4

Similar Publications

Rapid in situ carbon-13 hyperpolarization and imaging of acetate and pyruvate esters without external polarizer.

Commun Chem

October 2024

Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Killianstr. 5a, 79106, Freiburg, Germany.

Hyperpolarized C MRI visualizes real-time metabolic processes in vivo. In this study, we achieved high C polarization in situ in the bore of an MRI system for precursor molecules of most widely employed hyperpolarized agents: [1-C]acetate and [1-C]pyruvate ethyl esters in their perdeuterated forms, enhancing hyperpolarization lifetimes, hyperpolarized to P ≈ 28% at 80 mM concentration and P ≈ 19% at 10 mM concentration, respectively. Using vinyl esters as unsaturated Parahydrogen-Induced Polarization via Side-Arm Hydrogenation (PHIP-SAH) precursors and our novel polarization setup, we achieved these hyperpolarization levels by fast side-arm hydrogenation in acetone-d at elevated temperatures (up to 90°C) and hydrogenation pressures (up to 32 bar).

View Article and Find Full Text PDF

Hereditary Leiomyomatosis and Renal Cell Cancer (HLRCC) is an inherited cancer syndrome caused by germline pathogenic variants in the fumarate hydratase (FH) gene. Affected individuals are at risk for developing cutaneous and uterine leiomyomas and aggressive FH-deficient renal cell carcinoma (RCC) with a papillary histology. Due to a disrupted TCA cycle, FH-deficient kidney cancers rely on aerobic glycolysis for energy production, potentially creating compensatory metabolic vulnerabilities.

View Article and Find Full Text PDF

SABRE is emerging as a fast, simple and low-cost hyperpolarization method because of its ability to regenerate enhanced NMR signals. Generally, SABRE hyperpolarization has been performed predominantly manually, leading to variations in reproducibility and efficiency. Recent advances in SABRE include the development of automated shuttling systems to address previous inconsistencies.

View Article and Find Full Text PDF

Metabolic flux analysis of live cells using NMR enables the study of cancer metabolism and response to treatment. However, conventional NMR platforms require often prohibitively high numbers of cells to achieve significant resolution. In this work, we present a double H/C resonance NMR probe consisting of a solenoid coil with a less than 100 nL sensitive region.

View Article and Find Full Text PDF

Hyperpolarization-activated cyclic nucleotide-gated (HCN) ion channels generate electrical rhythmicity in various tissues although primarily heart, retina and brain. The HCN channel blocker compound, Ivabradine (Corlanor), is approved by the US Food and Drug Administration (FDA) as a medication to lower heart rate by blocking hyperpolarization activated inward current in the sinoatrial node. In addition, a growing body of evidence suggests a role for HCN channels in regulation of sleep/wake behavior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!