Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Up until now, gas permeation through polymers under high pressure has not been able to be measured continuously. The combination of a special high pressure cell and a commercially available fluorescence-based oxygen measurement system allows in-situ monitoring of oxygen permeation through a polymer sample under pressure in an aqueous environment. The principle of the oxygen sensor is based on dynamic fluorescence quenching and measurement of the fluorescence decay time. It was observed that the decay time increases non-linearly with the applied pressure, and hence, the displayed oxygen concentration has to be corrected. This deviation between the measured and the real concentration depends not only on the pressure but also on the absolute oxygen concentration in the water. To obtain a calibration curve, tests were performed in the pressure range between 1 and 2000 bars and initial oxygen concentrations in the range between 40 and 280 μmol/l. The polynomial calibration curve was of the fourth order, describing the raw data with a coefficient of determination R(2) > 0.99. The effective oxygen permeation through polymeric samples can be calculated with this function. A pressure hysteresis test was undertaken but no hysteresis was found. No temperature dependence of the oxygen sensor signal was observed in the range between 20 °C and 30 °C. This study presents for the first time data showing the oxygen permeation rates through a polyethylene film in the pressure range between 1 and 2000 bars at 23 °C.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4931399 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!