Assessment of the Accuracy and Cut-Failure Rates of Eye Bank-Cut Corneas for Use in Endothelial Keratoplasty: A Comparison of Outcomes Between 2010 and 2013.

Cornea

*Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD; †SightLife, Seattle, WA; ‡Department of Ophthalmology, Grady Memorial Hospital, Atlanta, GA; and §Department of Ophthalmology, Emory University, Atlanta, GA.

Published: November 2015

Purpose: To evaluate the accuracy of eye bank-prepared precut donor corneas over time by comparing cut-failure rates and corneal thickness measurements in 2010 and 2013.

Methods: A total of 2511 human corneas cut by a technician-operated mechanical microkeratome intended for endothelial keratoplasty were evaluated prospectively at one large eye bank facility in 2010 and in 2013. The endothelium was evaluated by slit lamp, and specular microscopy both before and after cutting was performed. Graft thickness as measured by pachymetry and/or optical coherence tomography was collected to assess the accuracy of the cut tissue. Cut-failure rates were compared between normal donor tissue and tissue with significant preexisting scarring.

Results: The combined cut-failure rate in 2010 and 2013 was 2.3% (23/1000) and 1.6% (24/1511), respectively (P = 0.23). The cut-failure rate among normal tissue in 2010 and 2013 was 2.0% (19/927) and 1.4% (19/1400), respectively (P = 0.24). The cut-failure rate among previously scarred tissue in 2010 and 2013 was 5.5% (4/73) and 4.5% (5/111), respectively (P = 0.74). The mean surgeon-requested graft thickness was 144.7 μm (range 100-150, SD 13.6) and 127.2 μm (range 75-150, SD 25.2) in 2010 and 2013, respectively (P < 0.0001). The mean deviation from target graft thickness was 21.3 μm (SD 16.3) and 13.6 μm (SD 12.5) in 2010 and 2013, respectively (P < 0.0001).

Conclusions: From 2010 to 2013, the combined cut-failure rates trended toward improvement, while the accuracy of graft thickness improved. This study suggests that the accuracy and success rates of tissue preparation for endothelial keratoplasty improve with experience and volume.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000000607DOI Listing

Publication Analysis

Top Keywords

2010 2013
32
cut-failure rates
16
graft thickness
16
endothelial keratoplasty
12
cut-failure rate
12
0
9
1
8
combined cut-failure
8
tissue 2010
8
μm range
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!