A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and finite element analysis of a novel sliding rod microscrew implantation device for mandibular prognathism. | LitMetric

Tooth distalization is an effective approach for mandibular prognathism. Current distalization devices are bulky and clinically complicated. Here, we designed a novel molar distalization device by using a sliding rod and a microscrew and performed a mechanical analysis and finite element model (FEM) analysis of force distribution and displacement of the upper canine, first and second premolar and first molar. A 2D FEM was constructed using the Beam3 element and a 3D FEM was constructed of the mandibular teeth, the periodontal membrane, and the alveolar bones using the UG software. The upper first molar was divided into 12 points on the dental surface to facilitate stress analysis. Force analysis using the ANSYS WORKBECNH revealed that, both horizontally and vertically, the traction force causing distalization of the first molar decreased when the spring coil moved down the L shaped sliding rod. The 3D FEM force analysis revealed distomedial displacement of the upper first molar when the sliding rod microscrew implantation device caused distalization of the molar. These findings support further exploration for the use of the sliding rod microscrew implants as an anchorage for group distal movement of the teeth of patients with mandibular prognathism.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4565243PMC

Publication Analysis

Top Keywords

sliding rod
20
rod microscrew
16
mandibular prognathism
12
finite element
8
microscrew implantation
8
implantation device
8
analysis force
8
displacement upper
8
fem constructed
8
upper molar
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!