Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions.

Eur Heart J Cardiovasc Imaging

Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA Department of Pathology, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA

Published: July 2016

Aims: The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied.

Methods And Results: In 2 independent laboratories with intravascular imaging expertise, 100 randomized matched data sets of IVOCT and IVUS images were analysed by 4 independent observers according to published consensus document definitions. Intra-observer, inter-observer, and inter-institute variabilities of IVOCT qualitative and quantitative measurements vs. IVUS measurements were assessed. Minor inter- and intra-observer variability of both imaging techniques was observed for detailed qualitative and geometric analysis, except for inter-observer mixed plaque identification on IVUS (κ = 0.70) and for inter-observer fibrous cap thickness measurement reproducibility on IVOCT (ICC = 0.48). The magnitude of inter-institute measurement differences for IVOCT was statistically significantly less than that for IVUS concerning lumen cross-sectional area (CSA), maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters (P < 0.001, P < 0.001, P < 0.001, P = 0.02, P < 0.001, and P = 0.01, respectively). Minor inter-institute measurement variabilities using both techniques were also found for plaque identification.

Conclusion: In the measurement of lumen CSA, maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters by analysts from two different laboratories, reproducibility of IVOCT was more consistent than that of IVUS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4907381PMC
http://dx.doi.org/10.1093/ehjci/jev229DOI Listing

Publication Analysis

Top Keywords

csa maximum
16
maximum minimum
16
ivoct
8
ivoct ivus
8
published consensus
8
consensus document
8
document definitions
8
intra-observer inter-observer
8
variabilities ivoct
8
reproducibility ivoct
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!