Background And Objectives: Endoscopic drainage is the first consideration in treating pancreatic fluid collections (PFCs). Recent data suggests it may be useful in complicated PFCs as well. Most of the available data assess the use of plastic stents, but scarce data exists on metal stent management of PFCs. The aim of our study to evaluate the efficacy and safety of a metal stent in the management of PFCs.

Patients And Methods: Data were collected prospectively on 47 patients diagnosed with PFCs from March 2007 to August 2011 at 3 tertiary care centers. These patients underwent endoscopic transmural placement of a fully covered self-expanding metal stent (FCSEMS) with antimigratory fins of 10 mm diameter.

Results: The stent was successfully placed in all patients, and left in place an average of 13 weeks (range 0.4-36 weeks). Etiology of the PFC was biliary pancreatitis (23), pancreas divisum (2), trauma (4), hyperlipidemia (3), alcoholic (8), smoking (2), idiopathic (4), and medication-induced (1). PFCs resolved in 36 patients, for an overall success rate of 77%. Complications included fever (3), stent migration (2) and abdominal pain (1).

Conclusions: The use of FCSEMS is successful in the majority of patients with low complication rates. A large sample-sized RCT is needed to confirm if the resolution of PFCs is long-standing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4568633PMC
http://dx.doi.org/10.4103/2303-9027.163000DOI Listing

Publication Analysis

Top Keywords

metal stent
16
endoscopic drainage
8
pancreatic fluid
8
fluid collections
8
fully covered
8
antimigratory fins
8
stent management
8
stent
6
pfcs
6
patients
5

Similar Publications

Bronchoscopic Closure of Bronchopleural Fistula with Occluder.

Cancer Manag Res

December 2024

Department of Pulmonary and Critical Care Medicine, the Affiliated Hospital of Yunnan Medical University, Key Laboratory of Respiratory Disease Research of Department of Education of Yunnan Province, Kunming, 650021, People's Republic of China.

Bronchopleural Fistula (BPF) represents one of the gravest complications post-lobectomy. Present treatment strategies encompass a wide array of surgical techniques complemented by essential adjunct therapies. Despite numerous treatment modalities, mortality rates associated with BPF remain disconcertingly high.

View Article and Find Full Text PDF

Aim This study aims to evaluate the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) check and revision procedures performed in a freestanding interventional radiology (IR) outpatient facility. Methodology A total of 40 patients (male 31:female 9, median age 60 years old) underwent a TIPS check and/or revision at a freestanding IR outpatient facility between 2009 and 2017. Procedures were performed using a mobile C-arm unit under intravenous (IV) moderate sedation, with the patient discharged home on the same day.

View Article and Find Full Text PDF

Adverse Events after Percutaneous Transhepatic Biliary Drainage: A Ten-Year Retrospective Analysis.

J Vasc Interv Radiol

December 2024

Department of Radiology, Section of Vascular and Interventional Radiology, Northwestern University, Chicago, IL. Electronic address:

Purpose: To determine the adverse events (AEs) rate associated with percutaneous transhepatic biliary drainage (PTBD) and identify risk factors for their occurrence.

Materials And Methods: This single-center retrospective study included 2310 PTBD (right-side: 1164; left-sided: 966; bilateral: 180) interventions for biliary obstruction (benign/malignant) in 449 patients between 2010-2020. Patients with percutaneous cholecystostomy alone were excluded.

View Article and Find Full Text PDF

: Contemporary treatments of acute aortic dissection, including medical, surgical, and endovascular options, are remarkably effective at the management of malperfusion and rupture. Unfortunately, long-term studies indicate that 30%-50% of patients need secondary procedures to treat progressive aneurysmal enlargement of the untreated aorta. The Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique was introduced to improve long-term outcomes.

View Article and Find Full Text PDF
Article Synopsis
  • The aim of the study was to create a reproducible animal model of tricuspid regurgitation (TR) using a self-expanding nickel-titanium stent.
  • The experiment involved 10 pigs, 7 in the experimental group undergoing TR induction through stent implantation, while 3 served as controls without the stent.
  • Results showed significant changes in cardiac structure and function in the experimental group, indicating successful model establishment with no fatalities, making this approach effective for further research on right ventricular issues.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!