Role of 'angle of progression' in prediction of delivery mode.

J Obstet Gynaecol Res

Epidemiology and Biostatistics Department, School of Public Health Sciences, Tehran University of Medical Sciences, Tehran, Iran.

Published: November 2015

Aim: The aim of this study was to investigate the role of the 'angle of progression' (AOP) in the prediction of vaginal delivery.

Material And Methods: In this prospective study, we followed 70 singleton pregnant women. AOP was measured at admission time and also at the beginning of the second stage immediately after digital examination. Digital and ultrasound examiners were unaware of each other's results. The digital examiner decided on the delivery mode based on clinical assessment.

Results: Sixty-five (92.9%) women had vaginal delivery. In the first stage of labor, the area under the curve was 87.5% (95% confidence interval [CI], 77.9-97.1; P = 0.005) for the AOP and 85.5% (95%CI, 75.2-95.6; P = 0.009) for digital examination and in the second stage of labor, the area under the curve was 90.2% (95%CI, 81-99.3; P = 0.003) for the AOP and 94.9% (95%CI, 89.1-100; P = 0.001) for digital examination. An AOP of ≥113° at the second stage was associated with a 90.8% probability of vaginal delivery.

Conclusion: We found a significant relation between AOP and cervical dilatation during the first stage of labor. A larger angle at the beginning of the second stage was significantly associated with shorter time to delivery.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jog.12798DOI Listing

Publication Analysis

Top Keywords

second stage
16
digital examination
12
stage labor
12
role 'angle
8
'angle progression'
8
delivery mode
8
labor area
8
area curve
8
stage associated
8
aop
6

Similar Publications

Background: Tuberculosis (TB) among women and infants during the perinatal period is not rare, particularly in countries with a high TB burden. And the risk would increase significantly following in vitro fertilization-embryo transfer (IVFET). Worse still, TB in this stage is apt to develop into severe forms in women and neonates, such as disseminated TB or tuberculous meningitis (TBM).

View Article and Find Full Text PDF

Background: Venous thromboembolic events (VTEs) are the second-leading cause of death in cancer patients, with an incidence of 5%-17% in lymphoma patients, particularly higher in those with non-Hodgkin lymphoma (NHL). Existing risk assessment models (RAMs) like the Khorana and ThroLy scores have limitations and are inadequately validated for NHL patients. Coagulation markers such as D-dimer, thrombin-antithrombin complex (TAT), and thrombomodulin (TM) show a potential predictive value for cancer-associated VTE but lack extensive research in NHL.

View Article and Find Full Text PDF

Centromedullary nailing during the second stage of induced membrane (Masquelet) for tibia septic nonunion enables bone consolidation to be achieved without increasing the risk of recurrence of infection, with an earlier return to weight-bearing.

Orthop Traumatol Surg Res

December 2024

Service de chirurgie orthopédique, Hôpital Nord, Pôle Locomoteur, Assistance Publique-Hôpitaux de Marseille, Institut du Mouvement et de l'Appareil Locomoteur, Marseille, France.

Introduction: Septic nonunion is one of the most feared complications in traumatology. Two-stage management using the induced membrane technique is a validated treatment option, but to date there is no consensus on the ideal type of osteosynthesis for the second stage of surgery. The aim of this study was to compare the results of two-stage treatment of tibial septic nonunion, depending on the type of osteosynthesis used.

View Article and Find Full Text PDF

Background: Occiput-posterior (OP) position is associated with labor arrest, need of operative delivery and failed instrumental vaginal delivery with resulting adverse peripartum outcomes. Vacuum extraction (VE) is the most commonly performed type of instrumental delivery worldwide. This study aimed to investigate the outcome of VE in fetuses with sonographically confirmed OP position prior to the procedure.

View Article and Find Full Text PDF

The oil spill is a significant source of marine pollution, causing severe harm to marine ecosystems. Detecting oil spills accurately using synthetic aperture radar (SAR) images is crucial for protecting the environment. However, oil spill targets in SAR images are small and resemble other objects "look-alike".

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!