Background And Objective: Spontaneous reporting systems (SRSs) remain the cornerstone of post-marketing drug safety surveillance despite their well-known limitations. Judicious use of other available data sources is essential to enable better detection, strengthening and validation of signals. In this study, we investigated the potential of electronic healthcare records (EHRs) to be used alongside an SRS as an independent system, with the aim of improving signal detection.
Methods: A signal detection strategy, focused on a limited set of adverse events deemed important in pharmacovigilance, was performed retrospectively in two data sources-(1) the Exploring and Understanding Adverse Drug Reactions (EU-ADR) database network and (2) the EudraVigilance database-using data between 2000 and 2010. Five events were considered for analysis: (1) acute myocardial infarction (AMI); (2) bullous eruption; (3) hip fracture; (4) acute pancreatitis; and (5) upper gastrointestinal bleeding (UGIB). Potential signals identified in each system were verified using the current published literature. The complementarity of the two systems to detect signals was expressed as the percentage of the unilaterally identified signals out of the total number of confirmed signals. As a proxy for the associated costs, the number of signals that needed to be reviewed to detect one true signal (number needed to detect [NND]) was calculated. The relationship between the background frequency of the events and the capability of each system to detect signals was also investigated.
Results: The contribution of each system to signal detection appeared to be correlated with the background incidence of the events, being directly proportional to the incidence in EU-ADR and inversely proportional in EudraVigilance. EudraVigilance was particularly valuable in identifying bullous eruption and acute pancreatitis (71 and 42 % of signals were correctly identified from the total pool of known associations, respectively), while EU-ADR was most useful in identifying hip fractures (60 %). Both systems contributed reasonably well to identification of signals related to UGIB (45 % in EudraVigilance, 40 % in EU-ADR) but only fairly for signals related to AMI (25 % in EU-ADR, 20 % in EudraVigilance). The costs associated with detection of signals were variable across events; however, it was often more costly to detect safety signals in EU-ADR than in EudraVigilance (median NNDs: 7 versus 5).
Conclusion: An EHR-based system may have additional value for signal detection, alongside already established systems, especially in the presence of adverse events with a high background incidence. While the SRS appeared to be more cost effective overall, for some events the costs associated with signal detection in the EHR might be justifiable.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4659852 | PMC |
http://dx.doi.org/10.1007/s40264-015-0341-5 | DOI Listing |
Drug Saf
January 2025
Department of Public Health Pharmacy and Management, Sefako Makgatho Health Sciences University, Pretoria, South Africa.
Introduction: The COVID-19 pandemic accelerated new vaccine development. Limited safety data necessitated robust global safety surveillance to accurately identify and promptly communicate potential safety issues. The African Union Smart Safety Surveillance (AU-3S) program established the Joint Signal Management (JSM) group to support identification of potential vaccine safety concerns in five pilot countries (Ethiopia, Ghana, Kenya, Nigeria, South Africa), accounting for approximately 35% of the African population.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China.
Precise and long-term electroanalysis at the single-cell level is crucial for the accurate diagnosis and monitoring of brain diseases. The reliable protection in areas outside the signal acquisition points at sharp ultramicroelectrode (UME) tips has a significant impact on the sensitivity, fidelity, and stability of intracellular neural signal recording. However, it is difficult for existing UMEs to achieve controllable exposure of the tip functional structure, which affects their ability to resist environmental interference and shield noise, resulting in unsatisfactory signal-to-noise ratio and signal fidelity of intracellular recordings.
View Article and Find Full Text PDFCarbohydr Polym
March 2025
Engineering Research Center of Chinese Ministry of Education for Edible and Medicinal Fungi, Jilin Agricultural University, Changchun 130118, China; College of Plant Protection and Mycology, Jilin Agricultural University, Changchun 130118, China. Electronic address:
Ganoderma tsugae, a traditional medicinal mushroom, exhibits anti-tumor properties; however, the effects of its polysaccharide on anti-colorectal cancer remain undetermined. Herein, a fucogalactan of Ganoderma tsugae (GTP-a2) was isolated and purified from its fruiting body. The molecular weight of GTP-a2 is 7.
View Article and Find Full Text PDFCarbohydr Polym
March 2025
Guangdong Provincial Key Laboratory of Construction and Detection in Tissue Engineering, School of Basic Medical Sciences, Southern Medical University, Guangzhou 510515, China. Electronic address:
The treatment and monitoring of infected skin wounds present significant clinical challenges. Herein, a multifunctional poly(deep eutectic solvent) (PDES) electroactive hydrogel is developed by optimizing the components and the ratio of hydrogen donors and acceptors, achieving well wound hemostasis, wound healing, and monitoring administration performace. The PDES hydrogel dressing exhibits mechanical properties, including high toughness, fatigue resistance (over 9000 compression cycles), and superior skin adhesion (over 70 kPa).
View Article and Find Full Text PDFACS Nano
January 2025
School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea.
Organic photodiodes (OPDs) are a significant focus for the next-generation of light-detection technologies. However, organic semiconductors in OPDs still face key challenges, such as low carrier mobilities and limited efficiency in generating photon-induced signals, which affect the detectable resolution and dynamic range. In this study, the characterization of the interaction between organic polymeric bulk heterojunctions and two-dimensional (2D) transition metal dichalcogenides (MoS) reveals an enhancement in photocurrent due to improved photogeneration dynamics (e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!