Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Laser-induced breakdown spectroscopy (LIBS) coupled with the linear multivariate regression method was utilized to analyze chromium (Cr) quantitatively in potatoes. The plasma was generated using a Nd:YAG laser, and the spectra were acquired by an Andor spectrometer integrated with an ICCD detector. The models between intensity of LIBS characteristic line(s) and concentration of Cr were constructed to predict quantitatively the content of target. The unary, binary, ternary, and quaternary variables were chosen for verifying the accuracy of linear regression calibration curves. The intensity of characteristic lines Cr (CrI: 425.43, 427.48, 428.97 nm) and Ca (CaI: 422.67, 428.30, 430.25, 430.77, 431.86 nm) were used as input data for the multivariate calculations. According to the results of linear regression, the model of quaternary linear regression was established better in comparing with the other three models. A good agreement was observed between the actual content provided by atomic absorption spectrometry and the predicted value obtained by the quaternary linear regression model. And the relative error was below 5.5% for validation samples S1 and S2. The result showed that the multivariate approach can obtain better predicted accuracy than the univariate ones. The result also suggested that the LIBS technique coupled with the linear multivariate calibration method could be a great tool to predict heavy metals in farm products in a rapid manner even though samples have similar elemental compositions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.54.007807 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!