We demonstrate how the optical transmission by a directly illuminated, sub-wavelength slit in a metal film can be dynamically controlled by varying the incident beam's phase relative to that of a stream of surface plasmon polaritions which are generated at a nearby grating. The transmission can be smoothly altered from its maximum value to practically zero. The results from a simple model and from rigorous numerical simulations are in excellent agreement with our experimental results. Our method may be applied in all-optical switching.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.23.022512DOI Listing

Publication Analysis

Top Keywords

optical transmission
8
dynamic control
4
control optical
4
transmission nano-slit
4
nano-slit surface
4
surface plasmons
4
plasmons demonstrate
4
demonstrate optical
4
transmission directly
4
directly illuminated
4

Similar Publications

Highly Green Fluorescent Carbon Dots from Gallic Acid: A Turn-On Sensor toward Pb Ions.

ACS Omega

January 2025

Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.

Carbon dots (CDs) are emerging novel fluorescent sensing nanomaterials owing to their tunable optical properties, biocompatibility, and eco-friendliness. Herein, we report a facile one-pot hydrothermal route for the synthesis of highly green fluorescent CDs using gallic acid (GA) as a single carbon source in ,-dimethylformamide (DMF) solvent, which serves as a nitrogen source and reaction medium. The optical properties of the synthesized GA-DMF CDs were systematically characterized by using UV-vis and photoluminescence spectroscopy, revealing strong green fluorescence.

View Article and Find Full Text PDF

Crystal Structural Editing: Novel Biaxial MgTeO Crystal as Zero-Order Waveplates.

Adv Mater

January 2025

State Key Laboratory of Crystal Materials and Institute of Crystal Materials, Shandong University, Jinan, 250100, China.

Waveplates are important optical components to control the polarization of light. Currently, they are often fabricated from uniaxial crystals, and there is no report about waveplates based on the biaxial crystals. In this work, a novel biaxial crystal MgTeO with a structure constructed by 0D TeO groups is designed and grown as waveplate materials for the first time.

View Article and Find Full Text PDF

Evaluation of tooth-specific optical properties for the development of a non-invasive pulp diagnostic system using Transmitted-light plethysmography: An in vitro study.

Arch Oral Biol

January 2025

Department of Pediatric Dentistry/Dentistry for Persons with Special Needs, Division of Oral Restitution, Graduate School, Institute of Science Tokyo, Japan.

Objectives: Transmitted-light plethysmography (TLP) is an objective and non-invasive pulp diagnosis method that has already been validated for applications for incisors. However, there is a demand for TLP use in the molars, it has not yet been established for this application. This study investigated the optimal light source wavelengths for TLP in premolars, to establish a pulp diagnosis system based on measuring pulpal blood flow.

View Article and Find Full Text PDF

The study aimed to compare the effects of different types of excimer laser keratectomy on rabbit corneas and to identify the optimal disease model for corneal ectasia. Additionally, investigating the structural and molecular alterations in the novel disease model helped explore the mechanisms underlying biomechanical cues in corneal ectasia. 2.

View Article and Find Full Text PDF

Integrated Spectral Sensitivity as Physics-Based Figure of Merit for Spectral Transducers in Optical Sensing.

Sensors (Basel)

January 2025

Department of Applied Physics and Science Education, Eindhoven Hendrik Casimir Institute, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands.

The design of optical sensors aims at providing, among other things, the highest precision in the determination of the target measurand. Many sensor systems rely on a spectral transducer to map changes in the measurand into spectral shifts of a resonance peak in the reflection or transmission spectrum, which is measured by a readout device (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!