Background: Buccal plate thickness is of clinical importance in treatment planning for implants. The purpose of this study was to evaluate the buccal plate thickness in posterior dentate areas of both the maxilla and mandible using cone beam computed tomography in order to estimate the approximate distributions of this anatomic variable.

Methods: Two hundred and sixty-five subjects were included for a total of nine hundred and thirty-four roots assessed by cone beam computed tomography. CBCT scans were taken and evaluated at the ideal buccolingual cross-sections of each root at 1 mm, 3 mm, and 5 mm apical to the alveolar crest to measure buccal plate thickness. Data are reported by geometric means and 95% confidence intervals.

Results: Both arches demonstrated increasing buccal plate thickness from anterior to posterior. Maxillary teeth had a significant decrease in thickness from coronal to apical along the tooth root (P < 0.001), except at second molars. The first premolar and mesial root of the first molar were significantly thinner than all other roots in the maxilla. Conversely, the mandible demonstrated a significant increase in buccal plate thickness from coronal to apical (P < 0.001). The premolars were significantly thinner than all other roots. Age and sex were found to have limited impact on buccal plate thickness in both arches.

Conclusions: Buccal plate thickness is highly dependent upon the arch position, tooth location, and measurement point, but age and sex have limited impact.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.12688DOI Listing

Publication Analysis

Top Keywords

buccal plate
20
plate thickness
20
cone beam
12
beam computed
12
computed tomography
12
tomography cbct
8
thickness
6
buccal
5
plate
5
cbct study
4

Similar Publications

Evaluation of sticky bone in guided bone regeneration in the aesthetic area of the anterior teeth: a retrospective study.

Int J Oral Maxillofac Surg

January 2025

Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:

The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.

View Article and Find Full Text PDF

This study aimed to develop a novel reconstruction method for segmental mandibulectomy. In the authors' opinion, reconstruction of the anterior border of the mandibular ramus using a double-arm vascularized fibular flap is important to prevent deformity due to buccal depression and the accumulation of food debris, thereby eliminating masticatory dead space that cannot be filled with prostheses such as implants or dentures. Using conventional reconstruction plates, the reconstructed bone positioned at the anterior border of the mandibular ramus required either fixing with only 1 screw or using 2 plates for stable fixation, making it difficult to position the plates stably.

View Article and Find Full Text PDF

This study aimed to develop a novel reconstruction method for segmental mandibulectomy. In the authors' opinion, reconstruction of the anterior border of the mandibular ramus using a double-arm vascularized fibular flap is important to prevent deformity due to buccal depression and the accumulation of food debris, thereby eliminating masticatory dead space that cannot be filled with prostheses such as implants or dentures. Using conventional reconstruction plates, the reconstructed bone positioned at the anterior border of the mandibular ramus required either fixing with only 1 screw or using 2 plates for stable fixation, making it difficult to position the plates stably.

View Article and Find Full Text PDF

Aim: To compare the microleakage in class V cavities restored with Activa Bioactive Restorative, Activa Pronto, and nanohybrid composite.

Materials And Methods: Standardized class V cavity preparations (mesiodistal: 3 mm; occlusocervical: 2 mm; axial depth: 1 mm) were made on the buccal surface of 60 extracted intact maxillary premolar teeth. The preparations were divided into three experimental groups ( = 20) depending on the restorative material used.

View Article and Find Full Text PDF

Background: Careful anatomical investigation of canalis sinuosus (CS) is essential to prevent damage to blood vessels and nerves in this area during surgical procedures, such as placing dental implants in the anterior maxillary region. This study investigated the relationship and distance between the CS and its adjacent structures.

Methods: A total of 400 cone-beam computed tomography (CBCT) images of Iranian adults aged 20-86 years were included in this retrospective study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!