A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nationwide Laboratory Adherence to Myocardial Perfusion Imaging Radiation Dose Reduction Practices: A Report From the Intersocietal Accreditation Commission Data Repository. | LitMetric

Objectives: This study sought to examine current laboratory practices for radiation effective doses for myocardial perfusion imaging (MPI) and laboratory adherence to guideline-directed radiation reduction practices.

Background: A recent focus on radiation dose reduction for cardiovascular imaging has led to several published guidelines and consensus statements detailing performance metrics for laboratory practices. We sought to examine laboratory adherence to optimized radiation dose protocol recommendations among 5,216 submitted cases from 1,074 MPI laboratories evaluated for Intersocietal Accreditation Commission accreditation.

Methods: Eligible imaging centers included MPI laboratories enrolled in the Intersocietal Accreditation Commission data repository of accreditation applications from 2012 to 2013. Accreditation requires submission of 3 to 5 cases for evaluation of a range of representative cases. Based on standard dosimetry for rest and stress MPI, an effective dose (in millisieverts) was calculated. Model simulations were performed to estimate guideline-directed effective doses.

Results: The average effective dose was 14.9 ± 5.8 mSv (range 1.4 to 42.4 mSv). A 1-day technetium Tc 99m protocol was used in 82.9% of cases, whereas a 2-day technetium Tc 99m and dual isotope protocol was used in 7.5% of submitted cases. Only 1.5% of participating imaging centers met current guidelines for an average laboratory radiation exposure ≤9 mSv, whereas 10.1% of patient effective doses were >20.0 mSv. A model simulation replacing the radiation exposure of dual isotope MPI with that of a 1-day technetium Tc 99m protocol reduced the proportion of patients receiving an effective dose >20 mSv to only 2.7% of cases (p < 0.0001).

Conclusions: Mandatory laboratory accreditation for MPI allows for examination of current radiation dosimetry practices. Current guidelines for reduced patient-specific radiation exposure are rarely implemented, with few laboratories meeting recommendations of ≤9 mSv for 50% of patients. Increased educational efforts and the development of performance measures for laboratory accreditation may be required to meet current radiation dose-reduction standards.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2015.07.008DOI Listing

Publication Analysis

Top Keywords

laboratory adherence
12
radiation dose
12
intersocietal accreditation
12
accreditation commission
12
effective dose
12
technetium 99m
12
radiation exposure
12
radiation
10
myocardial perfusion
8
perfusion imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!