The radiographic, or diagnostic, quality of the processed radiograph depends upon a number of factors, one of the most important being the characteristics of the film. The purpose of this study was to determine which of three intra-oral radiographic films, obtainable in this country, would give the best results in terms of density range, speed, contrast and base plus fog values. Agfa Dentus, Flow X-Ray and Kodak (all speed group D films) were exposed, using a calibrated G.E. 1000 x-ray generator at 65 kVp, 10 mA and 50 impulses (1 second) exposure time. The target-film-distance was 40 cm, the total filtration 2.0 mm Aluminium and the half-value layer 2.7 mm Aluminium equivalent. An aluminium step-wedge with 8 steps, in steps of 1.5 mm, and a natural premolar tooth, with a carious lesion, embedded in acrylic, were used as phantoms. An 8 mm-thick layer of base-plate wax and a 3 mm-thick lead plate were used to simulate tissue-scatter and prevent back-scatter, respectively. To determine the base plug fog value, an unexposed film from the same batch was processed simultaneously with each of the three films evaluated. All processing was done in a Dürr AC 245 L processor with automatic replenishment and a 6-minute cycle. The processing chemicals, viz., Kolchem High Stability X-ray developer and fixer, were mixed and used in strict accordance with the manufacturer's recommendations. The radiographic densities of each step of the step-wedge, and of carious and normal dentine of the phantom tooth, were determined by means of an RMI Digital Densitometer.(ABSTRACT TRUNCATED AT 250 WORDS)
Download full-text PDF |
Source |
---|
Orthod Fr
January 2025
Nantes Université, Université Angers, CHU Nantes, INSERM, CNRS, CRCI2NA, 44000 Nantes, France
Introduction: The aim of this article is to present the diagnostic and therapeutic approach to unilateral posterior vertical insufficiency.
Material And Methods: The authors describe the management protocol.
Results: Posterior vertical insufficiency (PVI) manifests clinically as obliquity of the maxillo-mandibular occlusal plane and bicommissural line, and deviation of the chin.
Natl J Maxillofac Surg
November 2024
Department of Orthodontics and Dentofacial Orthopaedics, Saraswati Dental College, Lucknow, Uttar Pradesh, India.
Introduction: The aim of the study was to evaluate the effectiveness of transcutaneous electric nerve stimulation (TENS) for controlling pain after the archwire placement and then comparison between the placebo, extra-oral, and intra-oral group depending upon the electrode placement.
Materials And Methods: The study consists of a sample size of 90 patients who were further divided into three groups. Each group had 30 samples each, and the groups were divided into placebo group, extra-oral TENS group, and intra-oral TENS group.
Clin Oral Investig
January 2025
Department of Oral and Maxillofacial Surgery, Radboud University Medical Center, Geert Grooteplein 10, Nijmegen, 6525, GA, the Netherlands.
Objectives: To assess the effect of patient positioning and general anesthesia on the condylar position in orthognathic surgery.
Materials And Methods: This prospective study included patients undergoing orthognathic surgery between 2019 and 2020. Four weeks prior to surgery (T0) cone-beam computed tomography (CBCT) scans and intra-oral scans (IOS) were acquired in an upright position.
Cureus
December 2024
Department of Oral Medicine and Radiology, Drs Sudha and Nageswara Rao Siddhartha Institute of Dental Sciences, Vijayawada, IND.
Background The thyroid gland is the most susceptible organ to radiation during the exposure of teeth because the thyroid area appears to be within the primary beam, and the dose levels are relatively high even after using collimation. This study aims to develop an eco-friendly thyroid shield by reusing lead foils from intra-oral periapical radiographic films and evaluate its effectiveness in intraoral radiography. Methods A total of 16 patients undergoing endodontic procedures who gave written consent to participate in the study were included and divided into four categories: anterior, canine, premolar, and molar.
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Dentistry Section Orthodontics and Craniofacial Biology, Radboud University Medical Center, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands.
Objectives: For this research two different ways for integrating intra-oral scans into three-dimensional (3D) stereophotogrammetric images are analyzed and compared to the gold standard method.
Materials And Methods: A cross-sectional study was performed. For each patient a complete dataset was collected, which was used to generate 3D fusion models by three different methods: method A using cheek retractors, method B using a tracer and method C using full-skull CBCT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!