Surface electrical stimulation (SES) is being investigated as a noninvasive method to evoke natural sensations distal to electrode location. This may improve treatment for phantom limb pain as well as provide an alternative method to deliver sensory feedback. The median and/or ulnar nerves of 35 subjects were stimulated at the elbow using surface electrodes. Strength-duration curves of hand sensation were found for each subject. All subjects experienced sensation in their hand, which was mostly described as a paresthesia-like sensation. The rheobase and chronaxie values were found to be lower for the median nerve than the ulnar nerve, with no significant difference between sexes. Repeated sessions with the same subject resulted in sufficient variability to suggest that recalculating the strength-duration curve for each electrode placement is necessary. Most of the recruitment curves in this study were generated with 28 to 36 data points. To quickly reproduce these curves with limited increase in error, we recommend 10 data points. Future studies will focus on obtaining different sensations using SES with the strength-duration curve defining the threshold of the effective parameter space.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1682/JRRD.2014.05.0128 | DOI Listing |
J Hazard Mater
January 2025
College of Environmental Science and Engineering, Donghua University, Shanghai 201620, China. Electronic address:
The transport of microplastics (MPs) is of great significance due to its potential threat to subsurface systems. The copresence of MPs and semi-conductor nanoparticles is quite common in practical environments (i. e.
View Article and Find Full Text PDFBioelectrochemistry
December 2024
Henan University of Chinese Medicine, Zhengzhou 450046, People's Republic of China.
Carcinoembryonic antigen (CEA) is a broad-spectrum biomarker, and its accurate detection and analysis is important for early clinical diagnosis and treatment. This study aimed to develop a highly sensitive and selective sandwich-type immunosensor based on electrochemical impedance spectroscopy (EIS) for the accurate detection of CEA. A novel composite material, gold nanoparticle/reduced-graphene oxide/graphitic carbon nitride (AuNPs/rGO/g-CN), was synthesized with excellent electrical conductivity and a large specific surface area to immobilize biological probes.
View Article and Find Full Text PDFPhysiother Res Int
January 2025
Department of Biomedical Engineering, University of Engineering and Technology (UET) Lahore, Narowal Campus, Narowal, Pakistan.
Background And Purpose: Throwing a baseball involves intense exposure of the arm to high speeds and powerful forces, which contributes to an increasing prevalence of arm injuries among athletes. Traditional rigid exoskeletons and rehabilitation equipment frequently lack portability, safety, ergonomic design, and affordability. Traditional rehabilitation approaches frequently require therapist monitoring, resulting in therapy delays.
View Article and Find Full Text PDFMicrosc Res Tech
January 2025
School of Electrical & Control Engineering, Shenyang Jianzhu University, Shenyang, China.
The atomic force microscope (AFM) image will be inclined and bent due to the tilt angle between the probe and the sample surface. When the least squares fitting method is used to correct the horizontal distortion of the AFM image, the shape structure that is lower or higher than the sample base will affect the final fitting correction result. In view of the limitations of existing methods and the diversity of AFM images, an AFM image level distortion correction method based on automatic feature marking is proposed.
View Article and Find Full Text PDFMicrosc Res Tech
January 2025
Department of Physics, East Tehran Branch, Islamic Azad University, Tehran, Iran.
SnO thin films were deposited on Si substrates by radio frequency (RF) magnetron sputtering technique, and the effects of different sputtering power (60-90 W) on the structural, surface morphological, and electrical properties of the film were investigated with XRD, Raman, AFM, SEM, and fore point probe. The deposited SnO film at lower RF was amorphous, while well-defined intense XRD signals at higher RF power indicated significant improvement in crystalline nature. E and A vibrating modes related to SnO were clearly observed in the Raman spectra.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!