Purpose: To compare surgical efficiency and multiple early clinical outcome variables in eyes undergoing phacoemulsification using either transversal or torsional ultrasound systems.
Setting: Assil Eye Institute, Beverly Hills, CA, USA.
Design: Prospective, randomized, clinician-masked, contralaterally controlled single-center evaluation.
Patients And Methods: Patients seeking cataract removal in both eyes with implantation of multifocal intraocular lenses were randomly assigned to one of two treatment rooms for phacoemulsification with either a transverse ultrasound system or torsional handpiece system. The contralateral eye was treated at a later date with the alternate device. A total of 54 eyes of 27 patients having similar degrees of cataract, astigmatism, and visual potential were included. All operative data were collected for analysis, and patients were followed for 3 months after surgery.
Results: Similar visual acuity was reported at all postoperative visits between the two groups. Mean phacoemulsification time and total power required were both significantly lower with the transverse system than with the torsional technique (P<0.05 for both). Similarly, mean total balanced salt solution used was significantly less with the transverse system vs torsional (P<0.05). Postoperative safety demonstrated significantly lower endothelial cell loss at 1 day and 1 month (P<0.05) with transverse vs torsional. Macular swelling was less at 1 week, 1 month, and 3 months with transverse vs torsional, although the difference did not achieve significance (P=0.1) at any single time point. Clinically detectable corneal edema was reported less frequently at all postoperative time points with the transverse system.
Conclusion: The transverse ultrasound system was found to be possibly associated with less balanced salt-solution use, less phacoemulsification time, and less power required than the torsional phaco system. Postoperative data suggested that improved phaco efficiency may translate to a better overall safety profile for the patient.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4529267 | PMC |
http://dx.doi.org/10.2147/OPTH.S86660 | DOI Listing |
Medicine (Baltimore)
January 2025
Department of Obstetrics and Gynecology, Minimally Invasive Gynecology Surgery Center, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan.
Rationale: Ovarian tumor torsion is a critical gynecological emergency, predominantly affecting women of reproductive age, with benign teratomas being the most common culprits. In contrast, malignant ovarian tumors, such as mucinous cystadenocarcinoma, infrequently present with torsion due to their invasive and angiogenic characteristics. The occurrence of torsion in malignant tumors complicates diagnosis and management, particularly when associated with complications like congestion, infarction, and internal bleeding.
View Article and Find Full Text PDFArch Gynecol Obstet
January 2025
Department of Obstetrics and Gynaecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, National Clinical Research Center for Obstetric & Gynaecologic Diseases, Beijing, China.
Purpose: To investigate the clinical characteristics and prognosis of surgically treated ovarian endometrioma (OMA) in pregnant women.
Methods: This retrospective cohort study analyzed 30 patients with pathologically confirmed ovarian endometrioma during pregnancy and delivery. Clinical characteristics and follow-up data were summarized.
Commun Med (Lond)
January 2025
Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Background: High-field magnetic resonance imaging (MRI) is a powerful diagnostic tool but can induce unintended physiological effects, such as nystagmus and dizziness, potentially compromising the comfort and safety of individuals undergoing imaging. These effects likely result from the Lorentz force, which arises from the interaction between the MRI's static magnetic field and electrical currents in the inner ear. Yet, the Lorentz force hypothesis fails to explain observed eye movement patterns in healthy adults fully.
View Article and Find Full Text PDFInt J Gynaecol Obstet
January 2025
Department of Radiology, Affiliated Hospital 2 of Nantong University, Nantong City, Jiangsu Province, China.
Objective: To develop and validate an individualized nomogram for predicting adnexal torsion in women with abdominal pain and an adnexal mass based on preoperative non-contrast computed tomography (CT) findings.
Methods: This retrospective study included 200 women with surgically resected ovarian lesions who underwent preoperative non-contrast CT for abdominal pain from January 2017 to September 2023 in seven hospitals. The 200 patients were randomly divided into a development group (140 cases) and a validation group (60 cases).
Vet Med (Praha)
December 2024
Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Jeollabuk-do, Republic of Korea.
Tibial torsion assessment is crucial for understanding deformities and malalignments that can lead to joint pathologies in dogs. Different methods such as radiography, computed tomography (CT), and three-dimensional (3D) volume-rendering techniques have been employed to measure tibial torsion. This study compared the accuracy and reliability of tibial torsion angle (TTa) measurements obtained using radiography and ultrasound tilting techniques against those obtained using the 3D volume-rendering method in small-to-medium-sized non-chondrodystrophic dogs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!