Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We developed a highly sensitive and specific high-performance liquid chromatography tandem mass spectrometry method with an electrospray ionization for the determination of D- and L-isomers of leucine in human plasma. Phosphate-buffered saline was used as the surrogate matrix for preparation of calibration curves and quality control samples. The extraction of D- and L-leucine in plasma samples (100 μL) was performed using cationic exchange solid-phase extraction. The enantiomer separation of D- and L-leucine was successfully achieved without derivatization using a CHIRALPAK ZWIX(-) with an isocratic mobile phase comprised of methanol/acetonitrile/1 mol/L ammonium formate/formic acid (500:500:25:2, v/v/v/v) at a flow rate of 0.5 mL/min. In addition, the discrimination of DL-leucine from structural isomers DL-isoleucine and DL-allo-isoleucine was performed using the unique precursor and product ion pair transition of DL-leucine (m/z 132.1 > 43.0) and DL-leucine-d 7 (m/z 139.2 > 93.0) in positive electrospray ionization mode. The standard curves were linear throughout the calibration range from 0.001 to 1 μg/mL for D-leucine and from 1 to 1000 μg/mL for L-leucine, respectively, with acceptable intra- and inter-day precision and accuracy. The stability of D- and L-leucine in human plasma and solvents was confirmed. The endogenous level of D- and L-leucine in human plasma was 0.00197~0.00591 and 9.63~24.7 μg/mL, respectively. This method was also successfully applied to investigate the species difference in the ratios of D-leucine to total leucine from individual plasma concentrations in humans and various animals. The plasma D-leucine concentrations or their ratio to total leucine in rodents was much higher than that in humans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-015-8999-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!