Left Ventricular Strain and Myocardial Fibrosis in Congenital Aortic Stenosis.

Am J Cardiol

Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts; Department of Pediatrics, Harvard Medical School, Boston, Massachusetts.

Published: October 2015

The aim of this study was to evaluate whether left ventricular (LV) systolic strain in children and young adults with congenital aortic stenosis (AS) and preserved ejection fraction was different from normal subjects and to determine whether any alterations in strain were related to myocardial fibrosis. In this retrospective study, 29 patients with congenital AS with a median age of 15.3 years (range 1.7 to 23.7), highest lifetime AS peak Doppler gradient of 73 mm Hg (22 to 110), most recent AS peak Doppler gradient of 49 mm Hg (0 to 90), and ejection fraction of 65 (55 to 79) were included. Strain was measured using 2-dimensional speckle-tracking echocardiography. Cardiac magnetic resonance was used to identify focal fibrosis by late gadolinium enhancement (LGE) and diffuse fibrosis by calculating the extracellular volume fraction (ECV) from T1 measurements. Compared to age-matched controls (n = 29), patients with AS had reduced LV longitudinal (17.0 ± 3.0% vs 20.6 ± 2.2%, p <0.001) and radial strain (28.8 ± 8.6% vs 34.9 ± 8.5%, p = 0.01), and similar circumferential strain (26.2 ± 5.9% vs 26.4 ± 3.9%, p = 0.79). Median ECV in patients with AS was 0.27 (0.22 to 0.38) and was not significantly correlated with systolic strain. Patients with LGE (n = 7) had lower longitudinal strain than those without LGE (n = 21; 15.0 ± 2.2 vs 17.7 ± 3.1, p = 0.036). In conclusion, in this cohort of children and young adults with congenital AS and preserved ejection fraction, longitudinal and radial strain were reduced, and decreased longitudinal strain was associated with LGE but not ECV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2015.07.042DOI Listing

Publication Analysis

Top Keywords

left ventricular
8
strain myocardial
8
myocardial fibrosis
8
congenital aortic
8
aortic stenosis
8
ejection fraction
8
peak doppler
8
doppler gradient
8
strain
4
ventricular strain
4

Similar Publications

The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.

View Article and Find Full Text PDF

Left ventricular rigor mortis interferes with postmortem aortic root geometry.

Int J Legal Med

January 2025

Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.

Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.

View Article and Find Full Text PDF

Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.

Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.

View Article and Find Full Text PDF

Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.

Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.

View Article and Find Full Text PDF

Pimobendan oral solution is bioequivalent to pimobendan chewable tablets in beagle dogs.

J Vet Intern Med

January 2025

Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.

Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.

Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?