Aims: The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with delayed arterial healing and impaired stent-related outcomes. The purpose of the present study is to compare directly the arterial healing response, angiographic efficacy and clinical outcomes between the Absorb BVS and metallic EES.
Methods And Results: A total of 191 patients with acute STEMI were randomly allocated to treatment with the Absorb BVS or a metallic EES 1:1. The primary endpoint is the neointimal healing (NIH) score, which is calculated based on a score taking into consideration the presence of uncovered and malapposed stent struts, intraluminal filling defects and excessive neointimal proliferation, as detected by optical frequency domain imaging (OFDI) six months after the index procedure. The study will provide 90% power to show non-inferiority of the Absorb BVS compared with the EES.
Conclusions: This will be the first randomised study investigating the arterial healing response following implantation of the Absorb BVS compared with the EES. The healing response assessed by a novel NIH score in conjunction with results on angiographic efficacy parameters and device-oriented events will elucidate disease-specific applications of bioresorbable scaffolds.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4244/EIJY15M08_03 | DOI Listing |
Cardiovasc Revasc Med
November 2024
U.O. Cardiologia Ospedaliera, IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy. Electronic address:
Background: Data on Absorb bioresorbable vascular scaffold (BVS) use in patients presenting with ST-segment elevation myocardial infarction (STEMI) are limited. Furthermore, Absorb studies including STEMI patients lacked a prespecified implantation technique to optimize BVS deployment. This study examines the 5-year outcomes of BVS in STEMI patients using an optimized implantation strategy and the impact of prolonged dual antiplatelet therapy (DAPT).
View Article and Find Full Text PDFJACC Cardiovasc Interv
August 2024
Hospital Universitario de La Princesa, Madrid, Spain. Electronic address:
Background: In patients with in-stent restenosis (ISR) bioresorbable vascular scaffolds (BVS) provide similar results to drug-coated balloons (DCBs) but are inferior to drug-eluting stents (DES) at 1 year. However, the long-term efficacy of BVS in these patients remains unknown.
Objectives: This study sought to assess the long-term safety and efficacy of BVS in patients with ISR.
Rev Cardiovasc Med
April 2024
Department of Vascular Surgery, Luhe Hospital Affiliated to Capital Medical University, 101199 Beijing, China.
This review aimed to explore the therapeutic effect of bioabsorbable stents in the inferior genicular artery, from the emergence of absorbable bare metal stents to the latest technology in polymer and anti-proliferative eluting drugs mixed with coated bioresorbable vascular stents (BVSs). Currently, there are conflicting data regarding the safety and effectiveness of BVSs in infrapopliteal artery interventions, especially compared to the current generation of drug-eluting stents (DESs). This review will cover the existing data on BVSs in reconstructing the infrapopliteal arterial blood flow and active clinical trials for future iterations of BVSs.
View Article and Find Full Text PDFExpert Rev Cardiovasc Ther
August 2024
The College of Medicine, Nursing and Health Sciences, University of Galway, Galway, Ireland.
Introduction: The higher scaffold thrombosis rates observed with the first-generation bioresorbable scaffolds (BRSs) compared to conventional drug-eluting stents were likely due in part to bioresorbable polymers having insufficient radial strength, necessitating larger strut profiles. Meta-analysis of the long-term outcomes from the first-generation Absorb bioresorbable vascular scaffold (BVS) showed that this period of excess risk ended at 3 years. Therefore, current attention has been focused on improving early outcomes by increasing the scaffold's tensile strength and reducing strut thickness.
View Article and Find Full Text PDFAdv Mater
August 2024
Medical Research Institute, Department of Orthopedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, 510080, China.
Magnesium, iron, and zinc-based biodegradable metals are widely recognized as promising candidate materials for the next generation of bioresorbable stent (BVS). However, none of those metal BVSs are perfect at this stage. Here, a brand-new BVS based on a novel biodegradable metal (Molybdenum, Mo) through additive manufacturing is developed.