A fast and efficient method for the simultaneous separation of highly polar compounds, in this case nucleosides and nucleotide mono-, di- and triphosphates, using hydrophilic interaction chromatography coupled with tandem mass spectrometry (HILIC-MS/MS) is proposed. This new separation method revealed the possibilities of the formation of hydrophilic ion-pairing compounds. Three stationary phases (HILIC XBridge-Amide, HILIC-CoreShell and ZIC-HILIC) were assayed for the separation of 20 target analytes, and a detailed study of the composition of the mobile phase was made using different salts at different concentrations in a organic-rich mobile phase. We report that in order to prevent the adsorption of nucleotides on the LC-MS setup and to enhance their retention on the HILIC stationary phase, a mobile phase containing hexafluoro-2-propanol and different cations should be used. Four cations were evaluated: ammonium, diethylammonium, triethylammonium and tetrabutylammonium. The results revealed the formation of an ionic-association compound between the phosphorylated analytes and the cationic ion-pairing reagents, whose retention increased with the polarity of the cationic ion-pairing reagent. HILIC XBridge-Amide was found to be the most suitable column for the separation of these analytes, and the optimized mobile phase consisted of an ACN/UHQ water mixture (3min of isocratic elution using 82:18%, v/v and then a fast gradient from 18% to 22% of water) with 100mM hexafluoro-2-propanol and 50mM diethylamine (w(w)pH 9-w(s)pH 10). In a total analysis time of 8min, good results were achieved in terms of resolution. Under these optimum conditions, a further comprehensive study of the retention mechanism was carried out.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2015.08.040DOI Listing

Publication Analysis

Top Keywords

mobile phase
16
hydrophilic interaction
8
interaction chromatography
8
chromatography coupled
8
coupled tandem
8
tandem mass
8
mass spectrometry
8
hydrophilic ion-pairing
8
ion-pairing reagents
8
nucleosides nucleotide
8

Similar Publications

Self-limiting selective phase separation of graphene oxide and polymer composite solution.

Nanoscale

January 2025

MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Key Laboratory of Adsorption and Separation Materials & Technologies of Zhejiang Province, Zhejiang University, Hangzhou 310027, China.

Homogeneous mixtures undergo phase separation to generate rich heterogeneous structures as well as enable complex physiological activity and delicate design of artificial materials. Beyond free space, the strong coupling between migrating components and spatial confinement plays a crucial role in determining the essential spatial compartment of phase separation, warranting further continuous exploration. Herein, we report the selective phase separation (SPS) behavior of polymers under a mobile two-dimensional (2D) confinement by graphene oxide (GO) sheets.

View Article and Find Full Text PDF

Background: Givinostat, a potent histone deacetylase (HDAC) inhibitor, is promising for the treatment of relapsed leukemia and myeloma.

Purpose: This study aimed to develop and verify a quick assay for the measurement of givinostat concentration using ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) with eliglustat as the internal standard (IS), establishing a basic pharmacokinetic profile for its pre-clinical application and metabolic stability in vitro.

Methods: Sample preparation was performed via protein precipitation using acetonitrile.

View Article and Find Full Text PDF

, a traditional Miao medicine, is commonly used by the renowned national-level Chinese Traditional Medicine practitioner Zhengshi Wu for the treatment of diarrhea due to its strong antioxidative, anti-inflammatory, and antidiarrheal effects. This study aimed to establish a high-performance liquid chromatography (HPLC) fingerprint for to provide new evidence and technical means for the scientific evaluation and effective quality control of . The procedure involved isolation with a Nano ChromCore C18 column (250 mm × 4.

View Article and Find Full Text PDF

Revealing New Analytical Insights into RNA Complexes: Divalent siRNA Characterization by Liquid Chromatography and Mass Spectrometry.

Anal Chem

January 2025

Synthetic Molecule Analytical Chemistry, Genentech Inc., South San Francisco, California 94080, United States.

Accurate characterization of therapeutic RNA, including purity and identity, is critical in drug discovery and development. Here, we utilize denaturing and non-denaturing chromatography for the analysis of ∼25 kDa divalent small interfering RNA (di-siRNA), which comprises a complex 2:1 triplex structure. Ion pair reversed-phase (IPRP) liquid chromatography (LC) experiments with UV absorbance and mass spectrometry (MS) showcase a single denaturing LC method for identity confirmation, impurity profiling, and sequencing with automated MS data interpretation.

View Article and Find Full Text PDF

White and Green Analytical Chemistry are innovative approaches in analytical chemistry that prioritize both sustainability and efficiency. Together, these approaches aim to advance scientific research while minimizing environmental impact and enhancing safety. This integration of environmental consciousness into analytical practices represents a significant step forward in achieving sustainable scientific progress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!